Technical data

5
Installation
SU54/5, SU80/5, SU100/5 – 6 720 808 532 (2013/08)12
Installing aquastat
Remove cover from the aquastat. To do so, undo the screw on the top.
If necessary, remove any unnecessary attachments. Attach bracket
[3] to aquastat [2] by means of two self-tapping screws [1].
Fig. 14 Attaching the aquastat to the bracket
[1] Self-tapping screws
[2] Aquastat
[3] Bracket
Feed the temperature sensor [4] with the compensating spring [3]
into the sensor well [5].
Attach bracket [6] to DHW tank by means of 4 self-tapping sheet
metal screws [1].
Replace the cover of the aquastat [2].
Fig. 15 Installing aquastat
[1] Self-tapping screws
[2] Aquastat
[3] Compensating spring
[4] Temperature sensor
[5] Sensor Well
[6] Bracket
Installing B-kit components
Fig. 16 Installing B-kit components
[1] Tee 1" x 1" x ¾ " (2x) with P&T safety valve
[2] Cap ¾ " for recirculation connection
[3] Bracket with aquastat
[4] Tee with fill and drain valve
6 720 800 155-03.1ITL
6 720 800 155-04.1ITL
5
4
3
2 1
6
6 720 801 769-04.1ITL
1
2
3
4