Instruction Manual

Table Of Contents
5
Installation
SM80/5, SM100/5 – 6 720 800 156 (2022/10) 11
Position the DHW tank on a level floor with adequate load-bearing
capacity.
Fig. 10 Positioning the tank
Maintain minimum wall clearances.
Using the adjustable foot, align the DHW cylinder vertically.
Remove the caps from the connections.
Fig. 11 Remove caps
Use Teflon tape or Teflon cord to seal the connections. Do not use
hemp to seal the connections.
5.2 Water connections
6 720 647 567-07.1ITL
WARNING: Risk of fire from soldering and brazing!
Take appropriate protective measures when
soldering and welding as the insulation is flammable,
for example, cover the insulation.
Check tank jacket for damage after completing work.
DANGER: Risk of injury from contaminated water!
Work carried out without due care for cleanliness
contaminates the drinking water.
Install in accordance with national standards and
guidelines.
NOTICE: Water damage
Connect the drain to the bottom tank connection
prior to filling the tank.
Seal off all unused tank connections.
NOTICE: Risk of corrosion from damage to the enamel
coating!
Attach connections to the DHW tank only "hand-
tight".
6 720 800 155-22.1ITL
A
B