SM100/5W Installation Manual

Table Of Contents
2
Product information
SM80/5, SM100/5 – 6 720 800 156 (2013/06) 7
2.6 Specifications
SM80/5 SM100/5
Lower coil
connected to a
boiler
Upper coil
connected to a
boiler
Both coils in
series with a
boiler
Lower coil
connected to a
boiler
Upper coil
connected to a
boiler
Both coils in
series with a
boiler
Tank capacity
Available capacity (total) gal
(l)
76.6
(290)
100.4
(380)
Maximum flow rate gpm
(l/min)
7.7
(29)
10
(38)
Maximum permissible DHW temperature °F
(°C)
203
(95)
203
(95)
Maximum permissible DHW operating pressure psi
(bar)
145
(10)
145
(10)
Stand-by heat loss (at 149 °F (65 °C) DHW
temperature, 68 °F (20 °C) room temperature)
°F/h
(K/h)
0.43
(0.24)
0.34
(0.19)
Tank performance:
Domestic cold water inlet temperature °F
(°C)
50
(10)
50
(10)
DHW outlet temperature °F
(°C)
140
(60)
140
(60)
DHW temperature rise °F
(°C)
90
(50)
90
(50)
Coil supply temperature °F
(°C)
176
(80)
176
(80)
Coil flow rate gpm
(l/h)
11.45
(2600)
11.45
(2600)
11.45
(2600)
10.57
(2400)
13.21
(3000)
11.45
(2600)
Coil pressure drop f o h
(mbar)
3.11
(93)
2.31
(69)
15.42
(162)
1
1. coil only, pressure drop of connecting pipe to be added
3.35
(100)
3.35
(100)
6.70
(200)
1
Continuous rating gph
(l/h)
gpm
(l/min)
134
(507)
2.2
(8)
105
(396)
1.7
(7)
215
(813)
3.6
(14)
209
(791)
3.5
(13)
129
(490)
2.2
(8)
305
(1153)
5.1
(19)
First hour rating gph
(l/h)
188
(710)
105
(396)
215
(813)
279
(1057)
129
(490)
305
(1153)
Maximum heat input to tank btu/hr
(kW)
100658
(29.5)
78479
(23)
161224
(47.3)
156959
(46)
97246
(28.5)
228784
(67.1)
Heat exchanger coil
Content gal
(liter)
2.32
(8.8)
1.64
(6.2)
3.96
(15)
3.20
(12.1)
1.85
(7)
5.05
(19.1)
Surface area ft
2
(m
2
)
13.99
(1.3)
9.69
(0.9)
23.68
(2.2)
19.38
(1.8)
10.76
(1)
30.14
(2.8)
Maximum heating water temperature °F
(°C)
230
(110)
230
(110)
Maximum coil operating pressure psi
(bar)
232
(16)
232
(16)
Table 5 Technical Data