SM100/5W Installation Manual

Table Of Contents
2
Product information
SM80/5, SM100/5 – 6 720 800 156 (2013/06) 5
2.2 Intended use
The DHW tank can be operated in a solar thermal system with a boiler as
a back-up, or for high output only with a boiler. (Operation of the two
heat exchanger coils in series or parallel.) The tank is designed for
heating and storing drinking water. Please observe national, regional,
and local codes, regulations, guidelines and standards for drinking
water. When operated as part of a solar system, the solar thermal system
must be filled with solar antifreeze to prevent frost damage.
The tank can be used only in closed loop systems and is not suitable for
drain-back solar thermal systems. Any other purpose is considered
improper use. Any resulting damage is excluded from the
manufacturer's warranty.
2.3 Product description
Fig. 2 SM80/5, SM100/5
2.4 Rating plate
The data plate is located at the top rear of the DHW tank.
Requirements
for potable water Unit
Water hardness, min. ppm
grain/US gallon
°dH
36
2.1
2
pH value, min. – max. 6.5 – 9.5
Conductivity, min. – max. μS/cm 130 – 1500
Table 3 Requirements for potable water
Item Description
1 DHW outlet
2 Boiler supply
3 Sensor well for temperature sensor, heat source or
aquastat
4 Recirculation connection
5 Boiler return
6 Solar supply
7 Sensor well for temperature sensor, solar
8 Solar return
9 Cold water inlet
10 Lower coil for solar thermal heating, smooth enameled
tubing
11 Inspection port for service and cleaning at the front
12 Magnesium anode with electrical insulation
13 Upper coil for reheating by heating appliance, smooth
enameled tubing
14 Tank, enameled steel
15 Built-in magnesium anode, without electrical insulation
16 PS top cover
17 Jacket, painted sheet metal with rigid polyurethane foam
insulation, 2" (50 mm)
Table 4 Product information
6 720 800 155-01.1ITL
1
10
11
15
16
4
7
8
9
2
3
5
6
14
13
12
17