Technical information
Transportation and Placement 5
9
We reserve the right to make any changes due to technical modifications!
Installation and Maintenance Manual Logalux LT135/2 – 300/2 • Issue 2013/08
Buderus Heiztechnik GmbH • http://www.heiztechnik.buderus.de
5.2 Moving the Tank Unpackaged
You can easily move the tank when you attach three car-
rying pipe stubs (not supplied) to the tank.
z Remove the 4 front panel screws (Fig. 5).
z Remove front panel. Pull the front and bottom of the
panel back.
z Remove insulating ring.
One carrying pipe stub (¾NPT) for the front of the
tank
z Screw a ¾“ coupling on a pipe end (Fig. 6, Item. 1).
z Tread coupling on front clean-out cover.
Two carrying pipe stubs (1“ NPT) on rear side of
tank
z Screw two 1“ coupling on two pipe ends (Fig. 7,
Item. 1).
z Screw carrying pipe stubs on boiler coil connections.
Fig. 5 Remove front cover
Fig. 6 Assembly of front carrying pipe stub
1
NPT¾
Fig. 7 Assembly of rear carrying pipe stubs
1
VS/RS RS/VS