Product Description3
3 Product Description
The LT135/2 - 300/2 indirect fired domestic hot water
tanks are factory assembled with exception of screw-on
feet (packaged with the boiler) and piping accessories
(packaged in envelope with tank) to be installed in the
field.
The major components of the tank are:
Tank vessel with corrosion protection
Corrosion protection is provided by hygienic Buderus
Thermoglaze "DUOCLEAN" as well as additional
cathodic protection using a magnesium anode rod
(Fig. 1, Item. 5), which is accessible by means of the
clean-out cover (Fig. 1, Item. 2).
Clean-out cover (Fig. 1, Item. 2) for maintenance
and service access.
Insulation (Fig. 1, Item. 3)
The insulation consists of high density polyurethane
directly attached to the tank vessel. An insulating
ring (Fig. 1, Item. 6) reduces heat loss from the
clean-out cover.
Domestic water temperature sensor bracket (when
using Buderus Logamatic control) (Fig. 1, Item. 4)
The sensor is strapped under the clip on the clean-
out cover for temperature control when using a
Buderus Logamatic control. When using a
Honeywell aquastat (not furnished), the coupling and
immersion well supplied are connected to the EZ
connection on the back of the tank.
Smooth surface heat exchanger
A smooth surface heat exchanger inside the tank
vessel transfers the energy from the boiler water to
the domestic water. The temperature in the tank will
be evenly distributed.
Fig. 1 Logalux LT135/2 – 300/2
Item. 1: Front cover
Item. 2: Clean-out cover
Item. 3: Insulation
Item. 4: Sensor bracket
Item. 5: Magnesium anode rod
Item. 6: Insulation clean out