Panel Radiator
Design Manual
Panel Radiator Design Manual | 12.2009
Technical specications are subject to change without prior notice
Thermostatic Sensor head:
Adding a Buderus Thermostatic Head enables room-by-
room zone control for optimum comfort and efciency. It
is easily installed on the ow setter valve.
A thermostatic head with remote sensor is available for
locations where the valve head would be covered behind
a curtain or otherwise blocked from sensing the actual
room temperature. Length of the capillary: 79“ (2000
mm).
Temperature Control:
Thermostatic control head is mounted on the ow setter
valve of panel radiators and towel racks, and through its
capillary expansion controls the ow rate and therefore
the heat output of the panel. When using the thermostatic
head the ow setter valve needs to be in the N position. A
moveable, spring-loaded seat assembly inside the ow
setter valve regulates the water ow through thermostatic
action of the control head. This thermostatic head is
required for individual temperature control at each
radiator. The asterics provides frost protection of the
panel itself provided the heating system is operational.
The sensor indicator numbers correspond to the following
approximate temperatures:
Thermostatic Sensor Head Setting Table 5
Dial * 1 2 3 4 5
Room Temperature °F 40 57 63 68 73 79
Room Temperature °C 5 14 17 20 23 26
2
1
3
4
Buderus
Buderus
Fig. 6 Thermostatic Sensor Head