User's Manual

Communication:
The RF/Dual Band Budderfly Outlets use the power line and the RF to communicate with the “Facility Controller”.
The outlets can reply to the following commands:
Join/Disjoin group “X”: The outlet will Join/Disjoin the group ”X”. Each outlet can be a member of several groups at the
same time.
Direct RTC synchronization: The outlet can receive a command to synchronize its “Real Time Clock”
Get Actual Measurement: When the outlet receives a “Get Measurement” command, it will send back to the facility
controller a string of data that contains:
- The Energy in kilowatt hour KWh
- The Power in Watt “W”.
- The Voltage in V
- The Current in Ampere “A”.
- A Timestamp.
Get Stored Measurement: The outlet will send back to the Facility Controller the stored electrical measurements.
Direct Reset Commands: The outlet can receive 3 types of reset commands:
- Hard Reset: This command will restart the device without affecting any stored parameter.
- Data Reset: This command will erase all the measurement and RTC data stored in the non-volatile memory.
- Group Reset: This command will remove the device from all the joined groups.
Group Reset Commands: The above reset commands can be directed to a group of devices instead of just one device.
Specifications:
Power: 120VAC/ 60Hz
Maximum Loads: 2400W, 20A (max), 1 HP.
Operating Temperature: 10
o
C to +40
o
C
Certification: UL and FCC Certification is in progress
For indoor use only
Warranty:
Budderfly LLC warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by
Budderfly is free of defects in material and workmanship under normal and proper use for a period of three (3) years from date of delivery to you.
Budderfly’s only obligation is to correct such defects by repair or replacement, at its option, if within such three year period the product is returned
prepaid via Budderfly’s Returned Materials Authorization (RMA) process to Budderfly LLC, Att: Quality Assurance Department, 2 Trap Falls Rd.,
SUITE 507 * SHELTON, CT 06484. In no case is product to be returned without first obtaining an RMA.
This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is
installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal
operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such
implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a
particular purpose, is limited to three years. Budderfly is not liable for incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. Budderfly’s
liability on any claim for damages arising out of in connection with the manufacture, sales, installation delivery, or use of the product shall
never exceed the purchase price of the product. The remedies provided herein are the exclusive remedies under this warranty, whether based on
contract, tort or otherwise.
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may cause undesired operation.
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS OR CHANGE TO THIS EQUIPMENT. SUCH MODIFICATIONS OR CHANGE COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.
Specifications subject to change without notice due to continuing product improvement.