Installation Guide

Page 3
LOCAL CODES
Install and use heater with care. Follow all local codes. In absence of local codes, use latest
edition of “The National Fuel Gas Code ANSI Z223.1”, also know as NFPA 54*.
*Available from:
American National Standards Institute Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT
INDENTIFICATION
MODELS C100BA(LP), C100BA(NAT) OR CVFB200(LP), CVFB200(NAT) MILLIVOLT
VENT FREE UNITS.
PRODUCT FEATURES
OPERATION
This heater is clean burning. It requires
no outside venting. There is no heat
loss out a vent or up a chimney. Heat is
generated by realistic, dancing yellow
flames. This heater is designed for vent
-free operation. State and local codes
in some areas prohibit the use of vent-
free heaters.
SAFETY PILOT
This heater has a pilot with an Oxygen
Depletion Sensing (ODS) safety
shutoff system. The ODS/pilot is a
required feature for vent-free room
heaters. The ODS/pilot shuts off the
heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This
system requires no matches, batteries,
or other sources to light heater.
STOVE
BODY
COVER DOOR
(SHOWN IN THE OPEN
POSITION)
OPTIONAL
REMOTE CONTROL
BRACKET
PIEZO IGNITOR
(FLAME) ADJUSTMENT
KNOB
NOTE: CVFB200 TOWNSEND II PICTURED
VALVE
CONTROL KNOB
AUTO
OFF
MANUAL
( HEPPLEWHIGHT )
AUTO
OFF
MANUAL
( TOWNSEND II )