Installation Guide
Page 17
OPERATING HEATER
Continued
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause property
damage, personal injury or loss of
life. Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
IMPROPER: Always operate the
appliance at the completely “ON” or
the completely “OFF” positions. Never
use the heater at a setting between these
positions as this can result in improper
combustion and excessive carbon
monoxide emissions.
Keep burner and control compartment
clean.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under
Lighting Instructions, page 16.
2. Depress control knob and light
pilot with match and lighter rod.
3. Keep control knob pressed in for
30 seconds after lighting pilot.
After 30 seconds, release control
knob. Now follow steps 8 through
11, page 16.
OPTIONAL REMOTE
CONTROL
NOTE: All remote control accessories
must be purchased separately (see
Accessories). Follow instructions
included with the remote control.
NOTICE: You must light the pilot
before using the remote control unit.
See Lighting Instructions on page 16.
PILOT FLAME PATTERN
(MILLIVOLT)
Figure 18 shows a correct pilot flame
pattern. Figure 19 shows an incorrect
pilot flame pattern. The incorrect pilot
flame is not heating the thermo-
couple. This will cause the thermo-
couple to cool. When the thermo-
couple cools, the heater will shut
down.
If pilot flame pattern is incorrect, as
shown in Figure 18:
Turn heater off (see To turn Off
Gas to Appliance, page 16)
See Troubleshooting, pages 20
through 22.
FIGURE 18 - CORRECT FLAME PATTERN L.P. OR NAT. GAS
FIGURE 19 - INCORRECT PILOT FLAME PATTERN L.P. OR NAT. GAS
THERMOPILE/
THERMOPILE/