Installation Guide
Page 8
INSTALLATION OF OPTIONAL BLOWER ASSEMBLY FOR
VENT FREE STOVE SERIES MODEL CVFB200(LP) OR CVFB200(NAT)
TOWNSEND II ONLY.
NOTE: If optional blower assembly is to be used
with heater , install blower assembly before putting
unit in chosen location and connecting gas supply.
CAUTION: The Blower Assembly is equipped
with a Power Cord. Make sure that the Power Cord
does not get under Blower Assembly or become
damaged while being installed.
WARNING: Electrical Grounding
Instructions: This appliance is equipped with a
three prong (grounding) plug for your
protection against shock hazard and should be
plugged directly into a properly grounded three
-prong receptacle. DO NOT cut or remove the
grounding from this plug.
1. Remove rear shield from top rear of unit before installing optional
Blower Assembly (MA CVF714).
2. Remove Blower Assembly from carton. Remove all protective
packaging applied to Blower Assembly for shipment.
3. Check all items for any shipping damage. If damaged, promptly
inform dealer where you purchased the Blower Assembly.
4. From the rear of the Fire Box, align four (4) notches in Blower
Assembly with (4) holes in rear of Fire Box. This will ensure
centering of Blower Assembly on the Fire Box. Attach Blower
Assembly to Fire Box using four (4) #8 x 1/2" self-piercing mounting
screws provided. (See Figure 5).
WARNING: Failure to position the parts in
accordance with this diagram or failure to use
only parts specifically approved may result in
improper functions or property damage or
personal injury.
CAUTION: Label all wires prior to
disconnection when servicing controls. Wiring
errors can cause improper and dangerous
operation.
Verify proper operation after servicing.
If any of the original wire as supplied with the
appliance must be replaced, it must be replaced
with a wire of at least a 105€ temperature rating.
WARNING: Only New Buck Corporation
approved blower assembly, part number MA
CVF714, may be used with Vent Free Stove
Series CVFB200(LP) or CVFB200(NAT)
Townsend II only.
BLOWER ASSEMBLY MODEL (MA CVF714)
NOTE: Do not run power cord underneath
heater or in walk way or heavy traffic areas.
FIRE BOX
VENT FREE STOVE SERIES MODEL CVFB200(LP) or
CVFB200(NAT) TOWNSEND II ONLY.
FIGURE 5 - LOCATION OF OPTIONAL BLOWER ASSEMBLY
FOUR (4) HOLES
FOR MOUNTING
BLOWER ASSEMBLY
REMOVE REAR SHIELD BEFORE
ATTACHING BLOWER ASSEMBLY
OPTIONAL BLOWER ASSEMBLY
(MA CVF714) FOR VENT FREE STOVE SERIES
TOWNSEND II FIREBOX (MODEL CVFB200LP,
CVFB200NAT) ONLY
FOUR (4) NOTCHES IN
BLOWER ASSEMBLY FOR
MOUNTING
BLOWER ASSEMBLY