Installation Guide

Page 21
Continued Removing Room Heater From ZC Cabinet
6. Facing the unit from the front, lift the room heater up and pull out by the front corners of the room
heater top. You must lift the room heater up high enough for the bottom to clear the brackets (front
stove stops) on the bottom front of the ZC Cabinet. NOTE: If you need more clearance to lift the
room heater inside the ZC cabinet at this point you may need to adjust the Flue Connector up more.
BRACKETS
(FRONT STOVE
STOPS)
REAR STOVE
STOPS
OUTSIDE AIR
ROD
STOVE
SUPPORT
RUNNERS
ELECTRICAL BOX
AND
RECEPTACLE
OUTSIDE
AIR INLET
FIGURE 17 MODEL 51ZC CABINET CUTOUT
NOTE: Before pulling the room heater out of the ZC cabinet you may need to place a drop cloth
where the heater is to be placed to protect your floor covering.
REINSTALLING THE MODEL 51, T-51, 74, T-74 ROOM
HEATER IN THE MODEL 51ZC CABINET
1. First lift the back of the room heater up and over the front stove stop brackets. The back of the
heater should rest on the support runners, keep the heater angled with the front lifted up and slide the
heater back into the ZC cabinet.
2. Slide the heater back until it stops at the back stove stops.
3. Next reattach the front stove stop brackets to the heater using the two (2) 3/8" head screws.
NOTE: The front stove stop brackets may have become bent while sliding the heater in and out of
the ZC cabinet, if so bend the brackets back in place and reattach as instructed.
4. Now you must reconnect the Flue Connector to the Model 51, T-51, 74, T-74 room heater. Run the
bottom nuts down almost to the end of the threaded rod. Align the Flue Connector with the room
heater and place it into the Flue collar. At this point you must run the top nuts down until they are
tight and the Flue connector is secure into the Flue Collar, then run the bottom nuts back up until
they are tight.