Installation Guide

Page 20
4. Remove the access cover door located at the bottom front of the room heater. There are two (2) phil-
lips head screws which must be removed, one (1) in each top corner of the access cover door.
5. Next, under the hearth on the left and right sides there are 3/8" head screws which attaches the room
heater unit to a bracket (Front Stove Stop) on the ZC cabinet. These two (2) screws must be re-
moved at this time.
NOTE: Disconnect the power cord from the receptacle inside the ZC cabinet before removing the
Model 51,T-51, 74, T-74 room heater. Do not damage the power cord while pulling the room heater out.
REMOVING MODELS 51, T-51, 74, AND T-74
ROOM HEATER FROM THE
MODEL 51ZC CABINET
At some point you may need to remove your Model 51, T-51, 74,T-74 room heater from the Model
51ZC cabinet, if so follow these instruction exactly. Remember if the room heater has been in use allow
time for cooling.
1. First remove the seven (7) 5/16" screws from the Top Front Trim. You may need a standard screw-
driver to lift one of the outer corners of the Top Front Trim before being able to remove it.
(See Page 22, Figure 18.)
1. Remove the three (3) 5/16" screws from the Right Side Trim. This will enable you to access the
power cord and receptacle, to disconnect the power supply to the room heater.
(See Page 22 ,Figure 18.)
1. Located between the room heater and the ZC cabinet is the Flue Connector. On each side of the Flue
Connector there is a threaded rod which is attached to the top of the ZC cabinet and has two (2)
9/16" nuts with a bracket between them that is attached to the Flue Connector. You will first need to
run the top nuts up the threaded rod about 1 1/4" (Do this on both the right and left side’s). Next run
TOP ADJUSTMENT
NUT
BOTTOM ADJUST-
MENT NUT
FLUE
CONNEC-
TOR
SLIP
COLLAR
BRACKETS
FLUE
COLLAR
BRACKETS
(FRONT STOVE STOPS)
POWER
CORD
RECEPTA-
CLE
FIGURE 16
AREA BEHIND ACCESS COVER
DOOR