Installation Guide
Page 10
CORNER LOCATION FRAMING
WARNING: Install the hearth protector only
as specified. The extension must extend a mini-
mum of 16" in front of the stove door opening
and must be 37 1/2" wide minimum. Refer to
(Page 6) for calculation of R, and K values.
NOTE: No floor protector is needed directly under the Model 51ZC Cabinet, only the hearth protector
is needed.
FIGURE 9
.
i
CHIMNEY CAP
STROM COLLAR
ROOF FLASHING
2" X 4" STUDDING
CHIMNEY PIPE
METAL FIRE STOP
USE FIRE CODE SHEET ROCK
2" X 4" STUDDING
A SINGLE HEADER MUST BE INSTALLED ABOVE CABI-
NET. VERTICAL 2" X 4"‘s MUST BE TURNED FLAT.
NOTE: FINISHED WALL MUST BE 2" IN FRONT OF FACE
OF ZC CABINET (WITHOUT HOOD TRIM ATTACHED).
NOTE: A DOUBLE HEADER MUST BE USED ON A LOAD
BEARING WALL.
34 3/4"
37 1/2"