Installation Guide

Page 9
1-B. Safety shields for brick or rock hearth: cut vertical
shield to fit installation height as needed. Use 26 GA.
Minimum metal being sure to cover any combustibles on
the base area.
ATTACH SAFETY SHIELD
USING SHEET METAL SCREWS
FIGURE 7-B
2. Set the Model 51ZC unit in place and attach the safety shield to the unit as shown in
Figure 7-A and Figure 7-B. You must use a non-combustible material or a UL listed floor
protector R-Value 0.6 (See Page 6). A minimum of 16" in front of stove door opening and 37 1/2"
the width of the cabinet (See Figure 8).
3. Frame the ZC Cabinet using 2" x 4" studs or local building code framing. Some minor framing
restrictions are required: Mantel Height (See Page 8 Figure 6 )
(A) Adjacent side walls must be at least 16" from the outer edge of the Cabinet trim panel.
(B) The overall opening dimensions must be at least 37 1/2" wide and 34 3/4" high and 26"
in depth.
(C) 2"x 4" framing above the unit must be turned flat. This allows proper clearance from framing
(2" minimum). (See Page 5 Figure 4.)
CONTINUED FRAMING AND INSTALLATION
NOTE: For raised hearth, safety shield must be
under cabinet (See Page 8, Figure 7-A).
Also shield must cover any face of combustible
material supporting cabinet where hearth connects.
(See Figure 7-B)
RAISED HEARTH
FIGURE 8
EXTERIOR ROOF OR CHASE
CHIMNEY
STORM COLLAR
ROOF FLASHING
CHIMNEY PIPE
USE FIRE CODE SHEET ROCK
2" X 4" STUDDING
DOUBLE HEADER: A DOUBLE HEADER
MUST BE USED ON A LOAD BEARING
WALL. THIS MUST BE DONE 12"
ABOVE CABINET.
SINGLE HEADER: A SINGLE HEADER
MUST BE USED AS PAT OF FRONT
FRAMING. VERTICAL 2" X 4"‘s
MUST BE TURNED FLAT.
34 3/4"
37 1/2"
WARNING: Install the
hearth protector only as speci-
fied. The extension must extend
a minimum of 16" in front of the
stove door opening and must be
37 1/2" wide minimum.
Refer to (Page 6) for calculation
of R, and K values.