The base for the Model 51ZC must be level with or slightly higher than the “finished” hearth height di-
mension (A) Figure 6.
Framing must be accomplished after the Model 51ZC is set in place. The chimney can be installed after
framing, but installation is considerably more difficult and in some cases, impossible. Therefore, it is
recommended that the chimney be installed prior to framing when a choice exists.
Figure 5 on the previous page shows framing location examples with depth dimensions for some typical
configurations. These are finished measurements so install accordingly.
NOTE: Before framing, combustible floor coverings (carpets, tiles, etc.) must be removed to outer
dimensions of the unit framing, including the 16" x 37 1/2" area for the hearth extension.
1-A. Safety shield for millboard hearth extension for
flat on the floor installation. Place (3") three inches
of safety shield under the ZC Cabinet. Place hearth
protector on top of safety shield.
FIGURE 7-A
FINISHED
HEARTH
WOODEN BASE
3" BACK FROM
FRONT OF UNIT
3" FORWARD FROM
FRONT OF UNIT
ATTACH 6" X 37 1/2"
SAFETY SHIELD
USING SHEET
METAL SCREWS
CONTINUED FRAMING AND INSTALLATION
WARNING: Install the hearth pro-
tector only as specified. The hearth ex-
tension must be a minimum of 16" in
front of the stove door opening and
must be 37 1/2" wide minimum.
(See page 6)
NOTE: No floor protector is needed
directly under the Model 51ZC Cabinet,
only the hearth protector. (See page 6)
NOTE: Safety Shield for
hearth extension must be
used on installation.
FIGURE 6
WOODEN BASE
2 1/2"
16"
FINISHED WALL
FINISHED
HEARTH
FLOOR
LINE
DIMENSION
(A)
MANTEL or SUPPORTS
“A MINIMUM OF 30 1/2" FROM
TOP OF UNIT TO TRIM OF
MANTEL OR SUPPORTS”
30 1/2"MIN.