Installation manual

Application
examples
SYSTEM DIAGRAM
4-zone large house with heating using 2 pumps with solenoid valves without
limit switches, and radiators.
L
ZONE 1
ZONE 2
ZONE 3
ZONE 4
1 2
BUS
Traditional cable
Hydraulic pipe
LEGEND
1 circulation pump zones 1 and 2
2 circulation pump zones 3 and 4
3 actuators zones 3 and 4 with pump
4 actuators zones 1 and 2 with pump
5 boiler
3
F430/2
F430/2
3
4
F430/2
4
F430/2
NOTE
For each zone one relay
controls the solenoid valve,
while the other is in parallel
on the circulation pump to be
controlled.
5
46
MY HOME TEMPERATURE CONTROL