226 MY HOME Energy management
CONTENTS MY HOME – Energy management General features. . . . . . . . . . . . . . . . . . . . . . 228 Temperature control . . . . . . . . . . . . . . . . . . . 235 Air conditioning. . . . . . . . . . . . . . . . . . . . . . 287 Energy consumption display. . . . . . . . . . . . . . 291 Load control management. . . . . . . . . . . . . . .
GENERAL FEATUREs saving energy has never been this easy MY HOME, the winning combination Displaying information on energy very much more aware of their consumption and managing and energy use, be it to meet their “green controlling energy loads; this is aspirations” or their desire to make whAT THE NEw My Home solutions financial savings deliver to end users - making them Visibility drives savings An aware user is one that saves changing there (bad) routines or with resulting benefits for the c
My Home enables you to: Create a living space with maximum comfort, only using the necessary energy and heat Improve the energy class of the building, and therefore also of its economic value Multimedia Touch Screen Touch Screen Energy management MY HOME 229
GENERAL FEATUREs To ensure energy efficiency with MY HOME is easy BUS-SCS MY HOME TV/SAT IPTV Heating only when and where needed Using this function, the user can decide the antifurto Zone temperature termoregolazione control videocitofonia controllo lan controllo carichi temperature of each individual room based on its energia luci tvcc use and the time of day It is also possible to select the rooms that are not being used, and therefore don’t need to be heated The activation of the system als
ne TV/SAT IPTV A complete consumption and energy production check-up The user can display on the touch screen not only the videocitofonia controllo lan controllo carichi Consumption energia display luci tvcc www irrigazione consumptions inside their home (power, water and gas1)), but also the energy and hot water ouput obtained using photovoltaic or solar panels uP to 15% sAVings With a few simple steps, the user can select the type of consumption that needs to be checked, the type of display (i
GENERAL FEATUREs Energy efficiency management devices overview Splitter Probe Local Display Splitter management interface 99 zone central unit Distribution board Room-by-room temperature control Zone temperature control Probe 99 zone central unit 232 MY HOME Energy management Air conditioning Splitter management Splitter interface Touch Screen
Washing machine Photovoltaic panel Thermal solar panels Microwave Flush mounted 16A actuator Bus meter with toroids Pulse counter interface Pulse counter interface Pulse counter interface Touch Screen Water meter with pulse output Gas meter with pulse output Automatic switching off of heating when windows are opened Consumption and production display Irrigation management Load control management m3/€ m3/€ KWh/€ Touch Screen KWh Kcal Central unit for load management Energy management MY HOME
234 MY HOME Energy management
CONTENTS MY HOME – Temperature control General features. . . . . . . . . . . . . . . . . . . . . . 236 General rules for installation . . . . . . . . . . . . . . 244 Wiring diagrams. . . . . . . . . . . . . . . . . . . . . . 249 Configuration . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL FEATUREs MY HOME temperature control can be used: WHEN THE SYSTEM IS PRESET Bathroom FOR ZONE MANAgEMENT Kitchen A system is preset for zone Bedroom management when the solenoid valves for the management of each zone can be installed on the distribution collector Hall Solenoid valve Living room A system is divided into Zones with radiant panel heating Collector Bedroom Collector Kitchen Bathroom Living room Box WHEN THE SOLENOID vALvES USED ARE: The solenoid valves that manage the T
IN SYSTEMS WITH: Radiators Radiant panels Fan-coil WITH SYSTEMS OF: Heating Bathroom Cooling Both Kitchen Bedroom IN CENTRAL HEATINg SYSTEMS WITH DISTRIbUTION COLLECTOR FOR EACH HOME In central heating systems where each Home is fitted with its own Hall distribution collector, it is possible to: Living room by installing a meter on the collector input, measure the amount of heat used; by installing solenoid valves, to manage the different zones of the Home Bathroom Kitchen Bedroom Hal
GENERAL FEATUREs Devices The MY HOME temperature control system consists of the following devices: Power supply Temperature central unit Probes: Probes they must be installed in each zone, Actuators so that the temperature of the rooms Contact interface (OPTIONAL) can be detected and if necessary locally changed, in relation to the temperature set on the control unit Power supply 99 zone central unit Power supply: Temperature control unit: for MY HOME systems this is the unit us
External temperature radio probe: it measures the external temperature and sends the information, through radio waves, to the receiving interface, Outdoor radio probe and therefore to the control unit Zone 2 probe External radio probe interface Zone 99 probe Local Display BUS 4 relay actuator Contact interface Actuators: Contact interface: For the ON/OFF control of the this optional device detects the open are open With this function one can solenoid valves only one contact is or closed posit
GENERAL FEATUREs Devices Adjustable probe TEMPERATURE CONTROL CENTRAL UNITS The two temperature control Local Display units ensure simple management/ programming of the whole system; in this way, thanks to a guided menu, it will be possible to select the operating mode, display the temperatures of the various zones, and change the possibility of managing the daily and weekly programs Inside the operating mode (OFF; antifreeze/ 4 zone control unit is a probe This thermal protection, and automatic
Video Station PERFECT INTEgRATION WITH THE MY HOME SYSTEM Example of integration between (e g weekly mode, external probe Temperature Control and Automation scenarioso mode, etc ) For further The temperature control system information see the User Manual can be integrated with MY HOME supplied as standard with Touch Automation, for the management screen IP of the temperature in the different zones of the house, using Touch Touch Screen screen, Videostation, and Video Display In particular, usin
GENERAL FEATUREs Device selection criteria gUIDE TO THE SELECTION OF THE CONTROL UNIT The following table shows the the number of zones of the hydraulic functions provided by the two system Other selection parameters control units The selection must be may be the management of magnetic based on the features of the system contacts, remote control, etc It is fundamental that the selection of the control unit should be based on available funCtionS 4 Zone Central unit 99 Zone Central unit HC/HS/L/N
gUIDE TO THE SELECTION OF THE DEvICES The following table summarizes the various types of systems, and the devices needed for their management, based on their features type of SyStem aCtuator probe HC/HS4692 L/N/NT4692 F430/2 F430/4 Gateway HC/HS4693 L/N/NT4693 HC/HS4692FAN L/N/NT4692FAN HC/HS4685 L/N/NT4685 In conjunction with probe item HC/ HS4693, L/N/ NT4693, or with external probe item 3457 Radiators or Radiant panels Combined system with radiant panels and fan-coils Normal Fan-coil CLIM
GENERAL RULEs FOR INsTALLATION Maximum number of devices, maximum distances and absorptions A system can manage up to 99 zone the items and making sure that the addresses Up to nine addresses total does not exceed the capacity dedicated to the actuators can of the power supply For the be managed for each zone The calculations mentioned above, refer on the BUs line the power supply maximum number of devices which to the TECHNICAL DATA listed in the should be installed in the middle can be connec
PHYSICAL EXPANSION MODE In large systems or systems which use of the interface itself as indicated have current absorption greater than below: Automation device addresses must the limit of 1200 mA supplied by the If a bus system with only be between A = 1 / PL = 1 and A = on the input bus (IN) the power supply E46ADCN or 600 mA temperature control devices must supplied by the E49 compact power be extended, positions I3 and I4 of supply, split the system into several the interface must be
General rules for installation Combining with other functions The Temperature control function The above is also valid if the this document. For systems which devices can share the same BUS pre-existing MY HOME system also have the burglar-alarm function, cable as other MY HOME automation has several Automation systems the Temperature control must not and emergency management connected using interfaces item F422 be installed on the same bus as the applications (grey cable).
Correct mode of installation for 4 zone control unit, probes and magnetic contacts The 4 ZONE CONTROL UNIT and wall-mounting boxes (LIVING, LIGHT, with pre-existing BUS systems that the Probes LIGHT TECH only); Surface installation cannot be expanded. must be installed at a height of may be useful for resolving issues approximately 1.
GENERAL RULEs FOR INsTALLATION Disposition of solenoid valves and actuators The typical installation requires the Solenoid valve actuators positioning of all solenoid valves on 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 ART.F430/2 C1 C2 1 2 3 4 1 2 3 1 2 3 4 4 ART.F430/2 C1 C2 1 2 3 4 ART.F430/2 C1 C2 ART.
Wiring diagrams Legend of symbols To make the reading of the diagrams shown in the following pages easier, the various symbols and their functions are summarised.
Wiring diagrams 4 zone villa DIAGRAM 1 HEATING WITH RADIATORS C4 C3 1 2 3 C2 4 C1 5 1 2 3 4 5 ART. F430/4 C1 C2 C3 C4 ZONE 4 -2 -1 OF F +3 +2 +1 Solenoid valve -3 F430/4 -2 -1 +1 Solenoid valve OF F +3 +2 ZONE 3 -3 4692 4692 -2 -1 +1 Solenoid valve OF +3 +2 ZONE 2 -3 BUS F E46ADCN 4692 18.0°C ZONE 1 Solenoid valve 23.7°C 13 : 38 C Ven 07 Gen OK 4695 1 2 3 4 1 2 3 4 ART.
Central unit/probe configuration 18.0°C 23.7 13 : 38 Ven °C 07 Gen OK C The 4 zone control unit item HD/HC/ the system configuration operations HS/L/N/NT4695 and item AM5875, correctly. as well as managing the whole of the As an alternative the TiThermo Basic temperature control system, contains application dedicated to this version a temperature probe which must of control unit can be used. be configured physically like the For these operations refer to the other system probes.
Wiring diagrams 4 zone villa DIAGRAM 2 Heating with Radiant panels C4 C3 1 2 3 C2 4 C1 5 1 2 3 4 5 ART. F430/4 -3 C1 C2 C3 C4 -2 -1 OF +3 +2 F +1 ZONE 4 F430/4 -3 4692 -2 -1 OF +3 +2 F +1 ZONE 3 4692 -2 -1 OF +3 +2 +1 ZONE 2 -3 BUS F E46ADCN 4692 18.0°C 23.7°C ZONE 1 13 : 38 C Ven 07 Gen OK 4695 1 2 3 4 1 2 3 4 ART.
Central unit/probe configuration 18.0°C 23.7°C 13 : 38 Ven 07 Gen OK C The 4 zone control unit item HD/HC/ correctly. As an alternative the HS/L/N/NT4695 and item AM5875, TiThermo Basic application dedicated as well as managing the whole of the to this version of control unit can temperature control system, contains be used. For these operations refer a temperature probe which must to the manual supplied with the be configured physically like the products. other system probes.
Wiring diagrams 4 zone villa DIAGRAM 3 Heating with Radiant panels and heating units C1 ZONE 1 C2 C3 4695 1 2 3 4 C4 5 1 2 3 4 5 ART. F430/4 18.0°C 23.7 °C 13 38 : Ven C1 07 C2 C3 C4 Gen OK C F430/4 4692 -3 ZONE 2 -2 -1 OF +1 +3 +2 F BUS -2 -1 OF E46ADCN F +1 +3 +2 ZONE 4 -3 4692 4692 -3 ZONE 3 -2 -1 +3 +2 OF F +1 1 2 3 4 1 2 3 4 1 2 3 C1 Mixing valve management central unit ART.
Central unit/probe configuration 18.0°C 23.7 13 : 38 Ven °C 07 Gen OK C The 4 zone control unit item HD/HC/ correctly. As an alternative the HS/L/N/NT4695 and item AM5875, TiThermo Basic application dedicated as well as managing the whole of the to this version of control unit can temperature control system, contains be used. For these operations refer a temperature probe which must to the manual supplied with the be configured physically like the products. other system probes.
Wiring diagrams 4 zone villa - Climaveneta fan-coil DIAGRAM 4 HEATING AND COOLING WITH CLIMAVENETA FAN-COIL (*) NOTE: the Gateway is fitted inside the FAN-COIL during manufacturing, and is already connected to the FAN-COIL itself through the collector found at the top on the front. Therefore, once the hydraulic connection has been completed, all that is needed is to connect the BUS.
99 zone central unit configuration OK 1 4 7 2 5 8 0 The 99 zone control unit item 3550 As an alternative the TiThermo does not need physical configurators application can be used. For these but, to end the system configuration operations refer to the manual operations, interact with the supplied with the products. “Configure zones” menu.
Wiring diagrams 4 zone villa DIAGRAM 5 HEATING AND COOLING WITH CLIMAVENETA AIR CONDITIONING AND COMBINATION BOILER (*) ZONE 4 -3 FAN-COIL connection -2 -1 OF +3 +2 F +1 4692FAN GATEWAY -3 (*) ZONE 3 -2 -1 OF +3 +2 F +1 4692FAN GATEWAY (*) NOTE: the Gateway is fitted inside the FAN-COIL during manufacturing, and is already connected to the FAN-COIL itself through the collector found at the top on the front.
next >> Heating and cooling with CLIMAVENETA FAN-COIL Electric diagram and configuration Correctly configures the gateway of the GATEWAY installed inside the corresponding to the zone as heating/cooling Climaveneta fan-coil. indicated in the configuration tables of the following pages. M GATEWAY BUS CLIMAVENETA CHILLER Wiring diagram of the gateway which There is thus no need to install The Gateway is connected to the controls the chiller.
WIRING DIAGRAMs 4 zone villa < previous DIAgRAM DESCRIPTION This diagram represents an example Using TiThermo set the Outside ON, Boiler OFF, valve open towards of a heating and cooling system Temperature (OT) value below which the Chiller To sum up, the Chiller made with Climaveneta unit and the Boiler starts to work: for example continues to work until the OT drops Combination boiler set 5°C below 5°C; at this point the Boiler By means of the TiThermo software When OT is higher than 5°C the
99 zone central unit configuration OK 1 4 7 2 5 8 0 3 6 9 The 99 zone control unit item 3350 This device does not need physical must be used to manage systems configurators but, to end the system with combination boiler. The configuration operations, interact function is not in fact available on with the “Configure zones” menu the 4 zone control unit item HC/ and with TiThermo applications. For HS/L/N/NT4695 and item AM5875. these operations refer to the manual supplied with the products.
Wiring diagrams 3 zone villa DIAGRAM 6 Heating with Radiant panels WITH WINDOW CONTACT MANAGEMENT C4 C3 C2 C1 F430/4 (*) 1 T - C1 - C2 4692 C1 5 C2 C3 C4 -2 -1 OF F +3 +2 +1 C2 C1 4 ART. F430/4 ART.F482 T 3 -3 C1 2 1 2 3 4 5 F482 (*) 4692 -2 -1 OF F +3 +2 C2 -3 ZONE 3 BUS +1 3550 ZONE 2 (*) T - C1 - C2 OK -2 -1 +1 C2 C1 2 5 8 0 OF +3 +2 T ZONE 1 1 4 7 ART.F482 -3 C1 E46ADCN 4692 F 3 6 9 F482 1 2 1 2 3 4 3 4 ART.
next >> 99 ZONE CENTRAL UNIT CONFIgURATION The 99 zone control unit item 3350 configurators but, to end the system When setting the parameters for must be used to use the magnetic configuration operations, interact the management of the magnetic contact management function The with the “Configure zones” menu contacts, the TiThermo application function is not in fact available on As an alternative the TiThermo must be used Two parameters may the 4 zone control unit item HC/ application can be used
Wiring diagrams 3 zone villa < previous Reactivation time The reactivation time can be set from Even if it goes against the concept of When the reactivation time is set on 5 to 55 minutes, or on unlimited. energy saving this function is useful unlimited the function is not active. When the time set has elapsed the when the windows have been left system reactivates the temperature open and the temperature set in the control zone even if windows or room must be kept the same.
PROBES configuration -3 Zone 1 probe -2 -1 +3 +2 OF F Zone 3 probe [ZA] [ZB] [SLA] [ZA] [ZB] [SLA] 0 1 - 0 3 - [ZA] [ZB] [SLA] 0 2 - +1 Zone 2 probe Actuators configuration Zone actuator 1 2 3 1 2 3 4 5 4 5 1 2 1 2 3 4 3 ART. F430/4 C1 C2 C3 C4 4 ART.
Wiring diagrams 3 zone villa DIAGRAM 7 Heating with Radiant panels WITH WINDOW CONTACT MANAGEMENT FROM THE BURGLAR-ALARM SYSTEM C4 C3 C2 C1 F430/4 F482 T - C 1 - C2 C1 5 C2 C3 C4 OFF +3 +2 +1 C2 C 1 4 ART. F430/4 ART.F482 T 3 -3 C1 2 1 2 3 4 5 -2 -1 (*) 1 4692 ZONE 3 -2 -1 OFF +3 +2 (*) C2 -3 4692 +1 3550 ZONE 2 T - C 1 - C2 E46ADCN 4692 OK ART.
next >> 99 ZONE CENTRAL UNIT CONFIgURATION In this case the contact interface is In order to use the function for performed using the “Configuration” connected to the burglar-alarm bus the management of the magnetic menu or the TiThermo application only and communicates with the contacts installed in the Burglar- When setting the parameters for temperature control bus by means of Alarm system, item 3550 must be the management of the magnetic interface F422 The door or window used in the conta
Wiring diagrams 3 zone villa < previous Reactivation time The reactivation time can be set from Even if it goes against the concept of When the reactivation time is set on 5 to 55 minutes, or on unlimited. energy saving this function is useful unlimited the function is not active. When the time set has elapsed the when the windows have been left system reactivates the temperature open and the temperature set in control zone even if windows or the room must be kept the same.
PROBES configuration -3 Zone 1 probe -2 -1 +3 +2 OF F Zone 3 probe [ZA] [ZB] [SLA] [ZA] [ZB] [SLA] 0 1 - 0 3 - [ZA] [ZB] [SLA] 0 2 - +1 Zone 2 probe Actuators configuration Zone actuator 1 2 3 1 2 3 4 5 4 5 1 2 1 2 3 4 3 ART. F430/4 C1 C2 C3 C4 4 ART.
Wiring diagrams 6 zone villa DIAGRAM 8 Heating with Radiant panels F430/4 1 2 3 4 F430/4 5 1 1 2 3 4 5 2 C1 C3 C4 C1 C2 C3 C4 C4 C1 4692 4692 -3 -2 -1 +1 -2 -1 +3 +2 +1 ZONE 3 ZONE 4 BUS 4692 4692 -3 -2 -1 +1 -2 -1 +3 +2 +1 ZONE 5 ZONE 2 4692 4692 -3 -2 -1 +1 -2 -1 +3 +2 ZONE 1 F430/2 +1 1 2 3 F430/2 4 1 1 2 3 4 2 C1 3 4 1 2 3 4 ART. F430/2 2 5 8 0 OFF +3 +2 OFF 3550 1 4 7 OFF +3 +2 OFF ZONE 6 OK OFF +3 +2 OFF -3 C3 5 -3 C2 4 ART.
99 zone central unit configuration OK 1 4 7 2 5 8 0 3 6 9 The 99 zone control unit item 3550 As an alternative the TiThermo does not need physical configurators application can be used. For these but, to end the system configuration operations refer to the manual operations, interact with the supplied with the products. “Configure zones” menu.
Wiring diagrams 6 zone villa DIAGRAM 9 RADIANT PANELS HEATING AND COOLING AND DEHUMIDIFIER FAN-COIL F430/4 1 2 3 4 F430/4 5 1 1 2 3 4 5 2 C1 C4 C1 5 C2 C3 C4 C4 C1 ZONE 3 -3 ZONE 2 BUS OFF +3 +2 -2 -1 +3 +2 4692 -3 +1 -2 -1 +3 +2 +1 4692 4692 -3 -2 -1 +1 -2 -1 +3 +2 OFF +3 +2 OFF +1 ZONE 6 Humidistat 1* OFF +3 +2 OFF -3 +1 ZONE 5 -3 4692 OFF 4692 C2 -3 ZONE 4 4692 -2 -1 C3 C3 +1 C2 4 ART. F430/4 -2 -1 C1 C2 3 1 2 3 4 5 ART.
99 zone central unit configuration OK 1 4 7 2 5 8 0 3 6 9 The 99 zone control unit item 3550 As an alternative the TiThermo does not need physical configurators application can be used. For these but, to end the system configuration operations refer to the manual operations, interact with the supplied with the products. “Configure zones” menu.
Wiring diagrams 8 zone villa DIAGRAM 10 HEATING WITH RADIATORS AND fan-coil COOLING F430/4 1 2 3 4 F430/4 5 1 1 2 3 4 5 2 C1 3 4 5 1 2 3 4 5 ART. F430/4 ART. F430/4 C2 C3 C4 C1 C2 C3 C4 BUS 4692 -3 -2 -1 +1 -2 -1 3 4 5 F430/4 +1 1 2 3 4 5 1 2 3 F430/4 5 1 2 3 4 5 ART. F430/4 C1 4 C4 OFF +3 +2 2 +3 +2 1 OFF -3 4692 C4 ART.
next >> HEATING Wiring diagram for connecting the solenoid valves of zones 2, 4, 6 and 8 to the heating actuator. To control zones 1, 3, 5 and 7 replicate the same connection between the solenoid valves and the corresponding to be controlled. In the example actuator. The configuration must given here, zone 2 is controlled by be made correctly, maintaining the contact C1 configured with [ZA] = 0 correlation between the actuator and [ZB] = 2.
Wiring diagrams 8 zone villa < previous 99 zone central unit configuration OK 1 4 7 2 5 8 0 3 6 9 The 99 zone control unit item 3550 As an alternative the TiThermo does not need physical configurators application can be used. but, to end the system configuration For these operations refer to the operations, interact with the manual supplied with the products. “Configure zones” menu.
Cooling system actuator configuration Zone 1 cooling actuator 1 2 3 1 2 3 4 5 4 5 ART.
Wiring diagrams Service sector, 12 zones DIAGRAM 11 2 PIPE, 3 SPEED FAN-COIL, SINGLE HEATING AND COOLING SYSTEM BUS F430/4 1 2 3 4 5 1 2 3 4 5 F430/4 ART. F430/4 -3 -3 -2 -1 OF +1 +1 F F OF F +3 +2 -2 -1 +1 4 OF -3 C2 C3 C4 5 +3 +2 3 4 ART. F430/4 C1 2 3 +3 +2 F430/4 1 2 -2 -1 C1 1 1 2 3 4 5 ZONE 10 C2 C3 C4 ZONE 12 ZONE 11 5 1 2 3 4 5 ART. F430/4 C1 C2 C3 C4 F430/4 1 2 3 4 5 1 2 3 4 5 F430/4 ART.
next >> HEATING AND COOLING Wiring diagram for connecting the zones replicate the same connection, fan-coil to the actuator for zone correctly configuring the actuator 12 heating/cooling. To control the corresponding to the zone as fan-coils belonging to all the other indicated in the configuration tables. ZONE 12 C4 C3 F430/4 1 2 3 1 2 3 4 5 C2 C1 M N 4 5 ART.
Wiring diagrams Service sector, 12 zones < previous Central unit/probe configuration OK 1 4 7 2 5 8 0 3 6 9 The 99 zone control unit item 3550 As an alternative the TiThermo does not need physical configurators application can be used. For these but, to end the system configuration operations refer to the manual operations, interact with the supplied with the products. “Configure zones” menu.
Heating/cooling fan-coil actuator configuration Zone 1 actuator 1 2 3 1 2 3 4 5 4 5 ART.
Wiring diagrams Several homes, 4 zones DIAGRAM 12 RADIATOR CENTRAL HEATING SYSTEM WITH Radiant panels OF Several homes, 4 zones Home n +1 -2 -1 +1 4692 ZONE 2 -3 -3 -2 -1 F OF +3 +2 OF +3 +2 ZONE 3 F 4692 18.0°C ZONE 1 23.7°C -3 ZONE 4 -2 -1 OF +3 +2 F 13 : 38 Ven 07 Gen OK +1 C 4692 4695 Home 2 +1 -2 -1 +3 +2 F +1 4692 OF +3 +2 OF ZONE 2 -3 -3 -2 -1 ZONE 3 F 4692 18.0°C 23.
next >> Connection of the distribution collector and temperature control BUS system of home 2 Solenoid valve C1 Solenoid valve C2 C3 C4 F430/4 1 2 3 1 2 3 4 5 4 5 ART. F430/4 C1 C2 C3 C4 Solenoid valve Solenoid valve Meter Mixing valve Mixing valve management central unit M 4 zone control unit F430/2 18.0°C 23.7°C 13 : 38 1 2 1 2 3 4 Main Solenoid valve 3 4 C ART.
Wiring diagrams Several homes, 4 zones < previous Central unit/probe configuration 18.0°C 23.7 13 : 38 Ven °C 07 Gen OK C The 4 zone control unit item HD/HC/ the system configuration operations HS/L/N/NT4695 and item AM5875, correctly. As an alternative the as well as managing the whole of the TiThermo Basic application dedicated temperature control system, contains to this version of control unit can a temperature probe which must be used.
TEMPERATURE CONTROL -ConfiguraTion General concepts The Temperature control system Zone ZA and ZB Probes address must be appropriately configured so Address of the devices belonging The probes also have positions ZA that it can work properly and so that to a logical zone; as an example in and ZB to define the address of the each item can perform the required a dwelling one can talk about night devices which will receive the control function. area, day area and cellar. (actuators).
Configurazione General concepts The probe which controls zone 1 is combined in the 4 zone control unit. ZONE 4 ZONE 3 07 Gen +1 Ven OF +3 +2 13 : 38 ZA = 0 ZB = 1 -2 -1 18.0°C 23.7°C -3 ZONE 2 ZONE 1 F ZA = 0 ZB = 2 OK C 4 zone central unit 18.0°C 1 23.7°C 13 : 38 Ven 07 2 3 4 1 2 3 4 ART. F430/2 Gen C1 ZA = 0 ZB = 1 N =1 1 2 3 ZA = 0 ZB = 1 N =2 4 1 2 3 4 ART. F430/2 C2 C1 1 2 3 4 1 2 3 4 ART. F430/2 C2 C1 ZA = 0 ZB = 1 N =3 C2 1 2 3 4 1 2 3 4 ART.