User's Manual

Table Of Contents
mBSC-C RU
mBSC0850i-040-RUC11 April 15, 2013
Page 36
Figure 32 Fiber Optic Cable Connection to RTM Enclosure
5. Route the patch cords from the fiber optic distribution box to the designated optical port on the
panel of the RTM enclosure.
6. Identify each optical fiber.
4.4.1.4 AC Power Connection
Danger
Use extreme caution when working with high voltage AC power. Ensure all power is disconnected before working on power
circuit.
Warning
Verify that the unit has been ground with an earth-bonding cable to the grounding connector.
A connectorized 3-wire power cable is provided with the RPM enclosures for the AC power connection, as
shown in Figure 36. The connectorized end of the power cable connects to the AC power port located on the
panel of the enclosure.
The AC power source must supply 110/220V AC(+/20% @50/60Hz) through a 15 Amp circuit breaker. The
AC power cable provides the wire leads for line, neutral and ground connections. The power cable must be
routed from the cabinet to an electrical junction box for connection to the AC power source. The power cable
is rated for indoor or outdoor use. Refer to the following procedure to install the AC power wiring:
1. Locate the RPM which is located at the multi-slot chassis of the Remote Node unite as shown in
Figure 35.