User's Manual
Table Of Contents
- Document History
- Revision History
- GENERAL SAFETY PRECAUTIONS
- TABLE OF CONTENTS
- LIST OF FIGURES
- LIST OF TABLES
- Introduction
- Figure 1Block Diagram of Host Unit
- Figure 2 Block Diagram of Remote Node
- Safety
- System Overview and Unit Description
- Figure 3mBSC System Functional Overview
- Figure 4 Host Unit
- Figure 5BIU
- Figure 6FIU
- Figure 7 PSU
- Figure 8RCU
- Table 1 Host Unit User Interface
- Front Panel
- Rear Panel
- Figure 10Fiber BCM Enclosure Outline
- Figure 11Fiber BCM Interior Layout
- Table 3BCM Enclosure User Interface
- Figure 12BCM Enclosure User Interface
- Table 4 Single-band RUM Enclosure User Interface
- Figure 14 Single-band RU Enclosure User Interface
- Table 5 Indicator Description
- Table 9Fiber RTM Enclosure User Interface
- Table 10 Indicator Description
- System Installation
- Figure 20 Mounting Brackets for 19” Rack Installation
- Figure 21Host Unit-19” Rack Mounting View
- Figure 22Host Unit Grounding Stud
- Figure 23 Grounded Host Unit
- Figure 24 BTS QMA Coaxial Cable Connection
- Figure 26E2000 Fiber Optic Port on Host Unit FIU
- Figure 27 48VDC Host Power Connection
- Figure 28IP Connection for local GUI Control
- Figure 29Modem Port on RCU (DB9 male)
- Figure 32 Fiber Optic Cable Connection to RTM Enclosure
- Figure 33 RPM
- Figure 36 Flow Chart of System Debugging
- System Monitoring &Configuration
- Figure 37– EMS Local GUI Login
- Figure 38- Main Page Expanded Topology
- Figure 39- Main Page Summary View
- Figure 40- RCU Component View
- Figure 41- Main Page Equipment Status
- Figure 42- FIU Optical Power Levels
- Figure 43- CM Optical Power Levels
- Table 16System Alarms
- Maintenance
- Figure 53Host Unit Trouble Shooting
- Figure 54Remote Unit Trouble Shooting
- Terms, Acronyms & Abbreviations
- IC Radiation Exposure Statement
- IC Déclaration sur la radio exposition
mBSC-C RU
mBSC0850i-040-RUC11 April 15, 2013
Page 31
5. Connect optical fiber to the Remote Node RTM fiber port.
4.3.2.4 DC Power Connection
The DC power interface of the Host Unit is provided by a 2-wire termination located on the HU rear panel. The DC
termination provides a connection point for the power cord which is provided separately with the HU. Use the
following procedure to install the DC power:
1. Locate the 48 VDC power cord which is provided separately with the HU.
2. Place both HU PS module power ON/OFF switches in the OFF position.
3. Connect one end of the power cord to the DC termination on the HU.
4. Connect the other end of the power cord to the 48VDC source.
5. Dress and secure cable per standard industry practice.
Figure 27 48VDC Host Power Connection
4.3.2.5 Local OMC Computer Connection
The primary communication interface between the mBSC system OMC and a local computer is provided by
a single RJ45 jack on the front panel of Host Unit (note: the USB port of the RCU card can also be used to
access the local OMC port). All the connected Remote Nodes can be monitored at the Host Unit side
through the fiber connection. The communication connector supports an IP interface. A CAT5 cable is used
for connecting the local computer to the mBSC Host Unit OMC interface.
To connect the OMC computer with the Host Unit:
1. Obtain the required length of CAT5 twisted pair cable with RJ45 connectors.
2. Route the cable between the OMC computer (or local switch/router) and Host Unit.
3. Connect the cable to the RJ45jack on the front panel of Host Unit RCU.
4. Connect the other end of the cable to the RJ45 jack on the OMC computer or local switch/router.