User's Manual
Table Of Contents
- Document History
- Revision History
- GENERAL SAFETY PRECAUTIONS
- TABLE OF CONTENTS
- LIST OF FIGURES
- LIST OF TABLES
- Introduction
- Figure 1Block Diagram of Host Unit
- Figure 2 Block Diagram of Remote Node
- Safety
- System Overview and Unit Description
- Figure 3mBSC System Functional Overview
- Figure 4 Host Unit
- Figure 5BIU
- Figure 6FIU
- Figure 7 PSU
- Figure 8RCU
- Table 1 Host Unit User Interface
- Front Panel
- Rear Panel
- Figure 10Fiber BCM Enclosure Outline
- Figure 11Fiber BCM Interior Layout
- Table 3BCM Enclosure User Interface
- Figure 12BCM Enclosure User Interface
- Table 4 Single-band RUM Enclosure User Interface
- Figure 14 Single-band RU Enclosure User Interface
- Table 5 Indicator Description
- Table 9Fiber RTM Enclosure User Interface
- Table 10 Indicator Description
- System Installation
- Figure 20 Mounting Brackets for 19” Rack Installation
- Figure 21Host Unit-19” Rack Mounting View
- Figure 22Host Unit Grounding Stud
- Figure 23 Grounded Host Unit
- Figure 24 BTS QMA Coaxial Cable Connection
- Figure 26E2000 Fiber Optic Port on Host Unit FIU
- Figure 27 48VDC Host Power Connection
- Figure 28IP Connection for local GUI Control
- Figure 29Modem Port on RCU (DB9 male)
- Figure 32 Fiber Optic Cable Connection to RTM Enclosure
- Figure 33 RPM
- Figure 36 Flow Chart of System Debugging
- System Monitoring &Configuration
- Figure 37– EMS Local GUI Login
- Figure 38- Main Page Expanded Topology
- Figure 39- Main Page Summary View
- Figure 40- RCU Component View
- Figure 41- Main Page Equipment Status
- Figure 42- FIU Optical Power Levels
- Figure 43- CM Optical Power Levels
- Table 16System Alarms
- Maintenance
- Figure 53Host Unit Trouble Shooting
- Figure 54Remote Unit Trouble Shooting
- Terms, Acronyms & Abbreviations
- IC Radiation Exposure Statement
- IC Déclaration sur la radio exposition
mBSC-C RU
mBSC0850i-040-RUC11 April 15, 2013
Page 30
Figure 24 BTS QMA Coaxial Cable Connection
5. Dress and secure cable at the Host Unit.
6. The RF inter-connection between the BIU and the FIU uses QMA to QMA jumper cables supplied
with the mBSC-C equipment.
4.3.2.3 Optical Connections
The optical interface between the Host Unit and the Remote Node is supported by an E2000/APC optical
adapter which is mounted on the FIU front panel. A single mode, E2000/APC patch cord may be used to
connect the Host Unit with Remote Node.
Use the following steps to connect the optical fibers:
1. Obtain one patch cord which is sufficient length to reach from Host Unit to the Remote Node.
2. Clean each patch cord connector following the patch cord supplier’s recommendation.
3. Push and secure the patch cord connector into the desired optical port on the Host Unit FIU
Figure 25Single Mode Patch Cord(E2000/APC)
Figure 26E2000 Fiber Optic Port on Host Unit FIU
4. Route the patch cords from the Host Unit to the Remote Node.