5.5.2 System Alarms
The MBSC1900-040-RU provides alarm indications for equipment malfunctions or for conditions that place
the out of standard operating range (such as over-power). A complete list of alarm events, and the
originating product module, is provided in Table 15 System Alarms.
These events are enabled by default factory settings, but can be disabled if desired.
These alarm events can be observed in multiples ways:
- In the EMS Local GUI in the network topology view and corresponding component parameter
windows
- In the Monitor window of the remote EMS Server
- As SNMP traps issued by the remote EMS Server (if enabled)
Table 15System Alarms
Item Equipment
Module
Alarm
ID
Alarm Name Description
1
Host Unit RCU
401500 Host/Remote Link
Optical RX signal is detected by the FIU
but no logical connection exists to the
Remote Node (CM)
2 423000 System Temperature
A system over-temperature alarm has
been reported
3
Host Unit FIU
401500 Host/Remote Link
Optical RX signal is detected by the FIU
but no logical connection exists to the
Remote Node (CM)
4 422000 Optical Transceiver 1
Low/No optical signal is detected on Link
1
5 422100 Optical Transceiver 2
Low/No optical signal is detected on Link
2
6
Remote
Node
CM
401500 Host/Remote Link
Optical RX signal is detected by the CM
but no logical connection exists to the
Host Unit (FIU)
7 423000 System Temperature
A system over-temperature alarm has
been reported
8 400100 Power Down
Power has been lost at the Remote Node
(internal battery backup enables alarm
delivery)
9
Remote
Node
RU
PA
401920 PA Over VSWR High VSWR detected at output of PA
10 427000 PA Over Output Power PA output power exceed threshold
11 401620 PA Over Driver PA overdrive condition exists
12 400600 PA Over Temperature High temperature condition in final PA