User's Manual
Table Of Contents
- 1 Introduction
- 2 Safety
- 3 System Overview and Unit Description
- 3.1 System Overview
- 3.2 Host Unit Description
- 3.3 Remote Node Description
- 4 System Installation
- 4.1 Unpacking and Inspection
- 4.2 Installation Preparation
- 4.3 Host Unit Installation
- 4.4 Remote Node Installation
- 4.5 Installation Final Inspection
- 4.6 System Test
- 5.1 Accessing EMS Local GUI
- 5.2 Navigating the EMS Local GUI
- 5.3 Installation & Configuration
- 5.4 System Tuning
- 5.5 Monitoring and Alarms
- 5.6 System Upgrade
- 6 Maintenance
- 7 Terms, Acronyms & Abbreviations
- 8 Packing List
mBSC2500U-005-RUCM11
MBSC2500U-005-RUCM11 April 15, 2013
Page 34
Figure 30 RF Inter-Connect between BCM and Single-band RU
4.4.1.1.2 Single-band RUM to RTM
To connect the coaxial cable between RTM enclosure and single-band RUM enclosure:
1. Obtain the required lengths of high performance, flexible, low loss 50Ω coaxial communication
cable for all coaxial connections.
2. Route the RF UL/DL path coaxial cable between the RTM enclosure and single-band RUM
enclosure interface and cut to the required length.
3. Connect the UL/DL cable to the designated UL/DL connector on the panel of RTM enclosure and
the panel of the single-band RUM enclosure.
4. Dress and secure cable.