User's Manual

mBSC DAS System
Installation Manual Issue 3
©20092011,BTIPage83
Figure 5-18. Adding a Slave Remote Unit
Table 5-2. Slots, Fiber and Type Values
Name Configuration Value
Slot Represents the slots on the HU from Left to Right that can be assigned to
various equipment. Slots 1-6 are reserved for the FIU and BIU.
Designating a slot number maps the RU to an FIU.
Fiber Maps the RU to the Fiber connection on the Host Unit to the associated
FIU.
Type Defines the frequency used and must match the RU type installed. There
are currently four different types of Remote Units. 700 MHz, 850 MHz,
1900 MHz, and 2100 MHz.
5.2.7 Connect Host Unit to Server
With the IP address updated, the Host Unit must be connected the server, Figure 5-19, for
communication information to function. The Host Unit is connected from the Network port on the back
interface through the hub to the server as shown in Figure 5-20 or may be directly connected from the
back interface port to the server. The Host Unit may also be connected to the server from the RCU
network port on the front interface, either directly or through the hub to the server. Only one network port
connection may be used at a time.