User's Manual

mBSC DAS System
Installation Manual Issue 3
©20092011,BTIPage22
4.2 REMOTE UNIT INSTALLATION
Danger: Wet conditions increase the potential for receiving an electrical shock when
installing or using electrical power equipment. To avoid electrical shock, never install or use
the electrical equipment in a wet location.
Danger: Do not look into the end of the fiber optic cables. Exposure to laser radiation may
result. Do not assume that the laser power is turned off or that the fiber optic cable is
disconnected at the other end.
Danger: Use extreme caution when working with high voltage AC power. Ensure all power
is disconnected before working on power circuit.
Caution: Always make sure there is sufficient cable length to permit the routing of the fiber
optic cables to prevent the cable damage. The optic cables may be damaged if bent or
coiled too tightly.
4.2.1 Remote Unit Installation Overview
The installation of the Remote Unit, both single enclosure and multi-enclosure, consists of the following
steps:
Table 4-1. Remote Unit Installation Overview
Step Operation Type Operation Action
1 MECHANICAL
INSTALL THE RU MOUNTING PANEL TO THE TOWER
2 MECHANICAL
VERIFY THAT THE SIDE MOUNTING BRACKETS ARE
SECURELY ATTACHED TO THE REMOTE UNIT
3
MECHANICAL
INSTALL THE MASTER REMOTE UNIT ON THE MOUNTING
PANEL
4 MECHANICAL
MOUNT THE SHROUD COVER OVER THE ENCLOSURE AND
SECURE IT
5
INSTALLATION
REVIEW
CONFIRM THE MECHANICAL INSTALLATION USING TABLE 4-4
MECHANICAL INSTALLATION CHECKLIST
6 ELECTRICAL GROUND THE UNIT
7 ELECTRICAL ROUTE THE CABLES TO BE CONNECTED
8 ELECTRICAL CONNECT THE FIBER OPTIC CABLES
9 ELECTRICAL CONNECT THE ANTENNA FEED LINE
10 ELECTRICAL INSTALL THE AC POWER CABLE
11 ELECTRICAL
CONNECT ANY SLAVE REMOTE UNIT TO THE MASTER
REMOTE UNIT
12
INSTALLATION
REVIEW
13 FIELD STATUS TEST
CONFIRM THE ELECTRICAL INSTALLATION USING TABLE 4-5
ELECTRICAL INSTALLATION CHECKLIST
CHECK THE REMOTE UNIT LED STATUS INDICATORS USING
TABLE 4-6 RU LED STATUS INDICATOR AND THE
TROUBLESHOOTING GUIDE
4.2.2 Installation Hardware And Tools
The Remote Units are shipped with the standard mounting hardware required for a BTI pole-mount