5.5.2 System Alarms
The mBSC0800S-005-RUCM11 provides alarm indications for equipment malfunctions or for conditions that
place the out of standard operating range (such as over-power). A complete list of alarm events, and the
originating product module, is provided in Table 16System Alarms.
These events are enabled by default factory settings, but can be disabled if desired.
These alarm events can be observed in multiples ways:
- In the EMS Local GUI in the network topology view and corresponding component parameter
windows
- In the Monitor window of the remote EMS Server
- As SNMP traps issued by the remote EMS Server (if enabled)
Table 16System Alarms
Item Equipment Module
Alarm
ID
AlarmName Description
1 401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheFIU
butnologicalconnectionexiststothe
RemoteNode(CM)
2
HostUnit RCU
423000 SystemTemperature
Asystemover‐temperaturealarmhas
beenreported
3 401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheFIU
butnologicalconnectionexiststothe
RemoteNode(CM)
4 422000 OpticalTransceiver1
Low/NoopticalsignalisdetectedonLink
1
5
HostUnit FIU
422100 OpticalTransceiver2
Low/NoopticalsignalisdetectedonLink
2
6 401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheCM
butnologicalconnectionexiststothe
HostUnit(FIU)
7 423000 SystemTemperature
Asystemover‐temperaturealarmhas
beenreported
408301 Fan1Alarm Fan1isnon‐functioning(lowcurrent)
408302 Fan2Alarm Fan2isnon‐functioning(lowcurrent)
8
Remote
Node
RTM
400100 PowerDown
PowerhasbeenlostattheRemoteNode
(internalbatterybackupenablesalarm
delivery)
9 401920 PAOverVSWR HighVSWRdetectedatoutputofPA
10
427000 PAOverOutputPower PAoutputpowerexceedthreshold