User's Manual
MBSC0800-040-RU
MBSC0800-040-RU April 15, 2013
Page 65
5.5.2 System Alarms
The MBSC0800-040-RU provides alarm indications for equipment malfunctions or for conditions that place
the out of standard operating range (such as over-power). A complete list of alarm events, and the
originating product module, is provided in Table 15System Alarms.
These events are enabled by default factory settings, but can be disabled if desired.
These alarm events can be observed in multiples ways:
- In the EMS Local GUI in the network topology view and corresponding component parameter
windows
- In the Monitor window of the remote EMS Server
- As SNMP traps issued by the remote EMS Server (if enabled)
Table 15System Alarms
Item Equipment Module
Alarm
ID
Alarm Name Description
1
HostUnit RCU
401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheFIU
butnologicalconnectionexiststothe
RemoteNode(CM)
2 423000 SystemTemperature
Asystemover‐temperaturealarmhas
beenreported
3
HostUnit FIU
401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheFIU
butnologicalconnectionexiststothe
RemoteNode(CM)
4 422000 OpticalTransceiver1
Low/NoopticalsignalisdetectedonLink
1
5 422100 OpticalTransceiver2
Low/NoopticalsignalisdetectedonLink
2
6
Remote
Node
CM
401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheCM
butnologicalconnectionexiststothe
HostUnit(FIU)
7 423000 SystemTemperature
Asystemover‐temperaturealarmhas
beenreported
8 400100 PowerDown
PowerhasbeenlostattheRemoteNode
(internalbatterybackupenablesalarm
delivery)
9
Remote
Node
RU
PA
401920 PAOverVSWR HighVSWRdetectedatoutputofPA
10 427000 PAOverOutputPower PAoutputpowerexceedthreshold
11 401620 PAOverDriver PAoverdriveconditionexists
12 400600
PAOverTemperature
Alarm
HightemperatureconditioninfinalPA
stage
13 427100 PALowerGainAlarm Lowgaincondition(<10dB)detected