mBSC-H DAS System
Installation Manual Issue 7
© 2009-2014, BTI Wireless Page 85
Figure 5-18. Adding a Slave Remote Unit
Table 5-2. Slots, Fiber and Type Values
Name
Configuration Value
Slot
Represents the slots on the HU from Left to Right that can be assigned to
various equipment. Slots 1-6 are reserved for the FIU and BIU. Designating
a slot number maps the RU to an FIU.
Fiber
Maps the RU to the Fiber connection on the Host Unit to the associated
FIU.
Type
Defines the frequency used and must match the RU type installed. There
are currently four different types of Remote Units. 700 MHz, 850 MHz, 1900
MHz, and 2100 MHz.
5.2.5.2 Modifying or Deleting a Remote Unit
Use the following steps to modify or delete a Remote Unit:
1. Select the Remote Unit from the System Net section.
2. To delete the Remote Unit, click Delete.
3. To modify the Remote Unit, enter the changes desired and press Modify. The Remote Unit caption,
Slot, Fiber and Type may be changed using the Modify button.