User's Manual
<-53dBc @±10MHz
@+25℃, Po=52dBm(max)
RF Gain
57.0 ± 1.0dB @ frequency range, +30Vdc, room temp.
Normal Operating Voltage +30Vdc±1.0Vdc
Operating Voltage
+29Vdc ~ +31Vdc
RF Gain Variation over
Voltage & Temperature
±1.5dB @ +29≤Vsup≤+31V, -20℃ to +50℃
Gain Flatness Peak to Peak 0.2dB over any 5MHz
Input/Output Return Loss
<-18dB
Output Protection
Mismatch protected with isolator
Efficiency ≥15%@+30Volts, Po=+52dBm
Operating Temperature -30℃ to +55℃ (Air Temperature inside System),
Operating point Output power:52dBm ± 0.5dB
Operating range 6dB min
Input Power ALC
Over Power
Output Pwr:52.5dBm ± 0.5dB
2. Alarm and Functions Specifications
TTL output for the alarm pins. Normal is High, Alarm is Low.
2.1. Over temperature alarm
Alarm and shutdown at 95℃ base temperature, auto-recover at 90℃ base temperat
ure.
2.2. Over power alarm
Alarm and shutdown when output power is over 52.5dBm, no auto-recover.
2.3. ALC
2.3.1. ALC level: 52±0.5dBm
2.3.2. ALC range: ≥6dB
2.4. VSWR alarm
Alarm and shutdown when reject is over 5, auto-recover at 3.
Part E, Declare