Installation Instructions
ITEM HT4105
3a
Hoses are attached to faucet body as
shown in diagram.
A - Blue Label Cold Water-In Hose
B - Faucet Stem
C - Hot Only Faucet, Hot Handle
D - Black Label Pressure Tank Hose
E - Hot & Cold Faucet, Cold Handle
F - Blue Label Cold Water-In Hose
G - Faucet Stem
H - Black Label Pressure Tank Hose
I - Hot & Cold Faucet, Hot Handle
A
C
D
E
F
G
H
I
B
3. BTI AQUA-SOLUTIONS HOT ONLY and HOT & COLD FILTRATION FAUCET W/ DIGITAL INSTANT HOT WATER DISPENSER
Drill 1-3/8” hole in countertop.
Maximum counter thickness is 2”
Center the base plate with built-in
O-ring over the mounting hole on
the top of the countertop. Center the
faucet body on the base plate.
If desired, apply a thin bead of silicone
seal under the base plate for added
sealing.
DO NOT USE PLUMBERS’ PUTTY
For Hot Only Faucet: Place faucet
handle in desired position.
Fasten the faucet from under the
countertop by rst sliding the rubber
washer, then the metal washer onto
the faucet stem.
Make sure to place the 3 screws on
the metal washer through the match-
ing holes of the rubber washer and
slide both washers up to the bottom of
the countertop.
3b
3c
3d
Place a metal pinch clamp on one
end of the clear hose and attach
the clear hose to faucet stem end.
Secure with pinch clamp.
3e
Attach the braided blue label cold-
water-in hose to cold-water supply
line.
Use plumbers’ tape on the outside
threads to provide a good seal.
3f
Thread the mounting nut to the top
of the faucet stem and hand tighten.
Once the faucet is secure, tighten the
3 screws against the underside of the
countertop. This will prevent the faucet
from moving/spinning.
Attach the braided black label
pressure tank hose to the blue
cold-water inlet on the dispenser.
Screw the tapered adapter onto the
red hot-water outlet. Use plumbers’
tape on the outside threads of the
outlet for a good seal.
Make sure that all lines are as straight
as possible and not kinked as this may
adversely affect the performance of
the dispenser.
Place the remaining metal pinch
clamp on the open end of the clear
hose. Push the clear hose onto the
tapered adapter previously installed
on the red hot-water outlet. Secure
with pinch clamp.
Turn on the water supply and check for leak(s), ESPECIALLY at the water supply and connections points. If leak(s) are present, shut off the
water supply, repair the leak and re-test the system as described. Open the hot handle of the faucet and turn on the water supply. Water
will ow from the faucet when the dispenser is full.
ENJOY YOUR BTI AQUA-SOLUTIONS FILTRATION
FAUCET AND DIGITAL INSTANT HOT WATER DISPENSER!
3g
3h
4