Unit installation

70
If a PA Silent zone is open when one of the setting routines starts, it is indicated
on the keypad display. The part that the open PA Silent zone is assigned to can
not be set.
PA Delay: If the PA Delay parameter is enabled, there is a 30 second delay be-
tween the activation of a PA zone and the alarm outputs firing. Resetting the PA
button during the delay period aborts the alarm. See Section 5: MENU OPTIONS:
Option 6 – Parameters; 06 User Options; 05 PA Delay
.
10 Dual
When the system is (Full) Set an alarm condition is generated if:
Two Dual zone activations occur within a 20 minute period. These
activations can occur on a single Dual zone or two separate Dual zones. A
single Dual zone activation, unless followed by another Dual zone
activation within a 20 minute period, will not cause an alarm and is not
recorded in the Event Log.
A single Dual zone remains active (2 k) for the entire 20 minute period.
When the system is Part Set the above two cases only cause a Local Alarm to
occur if the Part Bells and Part Intruder menu options are enabled, see Section 5:
MENU OPTIONS; Option 6 – Parameters; 06 User Options; 03 Part Bells and 04
Part Intruder
.
This zone type normally records only the active (+) events in the log after two
Dual zone activations, if the Zone Restoral attribute has been enabled it will record
both the active (+) and restore (–) events in the log, see Section 5: MENU OP-
TIONS; 6 – Parameters; 06 User Options; 13 Zone Restoral
. The first and sec-
ond activations of Dual zones record in the Log.
11 Security
This zone type is continuously operational.
When activated in the unset state, a Security zone causes a local alarm (keypad
buzzers, control panel horn and Security outputs activate). This can be cancelled
by any user code.
When the system is Part Set activation of a Security zone causes a local alarm to
occur unless the Part Bells and Part Intruder menu options are enabled in which
case a full alarm occurs, see Section 5: MENU OPTIONS; Option 6 – Parameters;
06 User Options.
Activation of a Security zone in the set state causes a full alarm condition that
requires to be reset with a code authorised for Intruder Reset. Refer to Section 5:
MENU OPTIONS; Option 4 – Codes and Option 6 – Parameters; 07 Reset.
This zone type records the active (+) and restore (–) events in the log.
12 Spare
This zone type has no function. The resistance value of Spare zones is not moni-
tored even when the system is set however it is strongly recommended that spare
zones have a 1k resistor connected across the zone terminals. Activation of the
Spare zone type does not record in the event log.
7 = Zones (cont’d)