Unit installation

62
Note: If the Intruder Reset attribute (Menu option 06 Perimeters; 07 Reset; 1
Intruder
) is disabled then any code may reset the system after an Intruder
alarm at any time).
Star Abort
When enabled, the Star Abort provides a time period during which any user
(with or without the Reset parameter enabled) may prevent an Intruder alarm.
This will last until the end of the untry time.
If a user strays from the Entry route and causes an alarm then the Bell and
Strobe outputs (but not Intruder) activate.
If no valid code has been entered when the Entry Time or Star Abort Time
(whichever is shortest) has expired then the Intruder outputs activate.
Once the Star Abort Time or Entry Time (whichever is shortest) has elapsed
then a valid user code with the Resets attribute enabled is required to reset
the system and deactivate the Intruder output.
Note: If the Intruder Reset attribute (Menu option 6 – Parameters; 07 Reset; 1
Intruder
) is disabled then any code may reset the system after an Intruder
alarm at any time).
08 Part Set
When the Part Set attribute is disabled then Exit/Entry zones act as Entry Time
countdown initiators when the system is Part Set. If enabled then Exit/Entry
zones will as Intruder zones when the system is Part Set.
The Exit/Entry zones always act as Intruder zones when the system is Full Set.
The Part Set attribute also affects the operation of the Set output type. When
disabled (default) the Set outputs do not activate when the system is Part Set.
When enabled the Set outputs activate when the system is Part Set. The Set
outputs always activate when the system is Full Set (all three parts are set).
09 Line Fail High (Galaxy 16 only)
This option determines the condition that activates the line fail zone. When
disabled, it will activate on a high to low transition.
09 Sig. Log Full (Galaxy 16
plus
only)
Signals that Log is 90% full. This will also be signalled via SIA format communi-
cations (if in use).
10 Reset Manager
Resets the Manager Code (Usr 14) to default (1234). Pressing the # key enables
this option (denoted by the box being filled). The Manager Code will not reset
until the ent key is pressed while this option is enabled. This option automati-
cally resets to disabled once it has been executed.
11 Part Silent
When enabled this will silence the keypad horns and Horn type outputs during
a Part Set.
6 = Parameters (cont’d)