Unit installation

56
Option 5 – Test
This test is only available in full for the Engineer Code, the Manager Code also
has limited access, all other User Codes have no access, see Table 5.4 Test
Outputs.
This option allows the output devices connected to the system to be tested.
Outputs are tested by function. When 5=Bells is selected for test, all outputs
programmed as Bells activate. Refer to Option 8 – Outputs for details on the
programming of the outputs.
When the Test option is selected by the engineer, test 01 FIRE is displayed.
Press the A or B key to move to the required test. To test the programmed
outputs, press the # key. Outputs programmed to the corresponding function
are switched on. To end the test, press the # key; the tested outputs switch off.
Use the A or B key to select another test.
Table 5.4 Test Outputs.
Figure 5.9 Fire Output Test Statuses.
Note: Pressing the test number key (2 – 9) directly starts the test of the
corresponding outputs. Press 01 to test the Fire output, 10 to test the Confirm
output and 11 to test the Medical output.
To exit from the Test option press the esc key.
The Test option automatically terminates if a test is allowed to run for two
minutes or if no tests are selected within two minutes of the last key-press.
5 = Test
1
zz
zz
z
FIRE
TEST
01
FIRE
#, 01 = TEST
# or 01 to toggle
Fire Test status
(a) Fire Outputs Test disabled (b) Fire Outputs Test enabled
epyTtuptuO.oNtseT
eriF10
AP20
redurtnI30
teS40
slleB
50
ebortS
60
CDhctiwS70
ytiruceS80
mrifnoC90
nroH01
lacideM11
liaFCA21
AkniL31
BkniL41
woLttaB51
repmaT61
timOenoZ71
.tsetotsseccasahedocrgM