Unit installation
10
Figure 1.10 Zone to Multiple Detector Wiring.
Wiring Keyswitches
Keyswitches require to be latching, the transition from 1 kΩ to 2 kΩ initiates
the setting procedure of an unset system; if the system is already set, then the
transition from 1 kΩ to 2 kΩ has no effect.
The transition from 2 kΩ to 1 kΩ instantly unsets a set system, if the system is
unset, the transition from 2 kΩ to 1 kΩ has no effect. The wiring of the
keyswitch is shown in Figure 1.11 Keyswitch and Terminator Zone Wiring.
Wiring Exit Terminators (Push-to-Set)
Push-to-Set buttons can be open going closed (2 kΩ to 1 kΩ) or closed going
open (1 kΩ to 2 kΩ). The wiring of the terminator is shown in Figure 1.11
Keyswitch and Terminator Zone Wiring.
Figure 1.11 Keyswitch and Terminator Zone Wiring.
Wiring Multiple Zones
Multiple detectors can be wired into a single zone as shown in Figure 1.10 Zone
to Multiple Detector Wiring. It is recommended that the maximum number of
detectors wired into a single zone is ten.
Keyswitch Wiring
Zone
Alarm
Alarm Alarm Alarm
N/C
N/C
N/C N/C
N/C TAMP
1k
1k
1k
1k
1k
1%
1%
1% 1%
1%
N/C
500 m
(10 max)
Keyswitch
zone
Push-set
zone
1k to unset, 2k to set
1k
1%
Open - Closed
1k
1k
1k
1k
500m
OR
Closed - Open
1%
1%
1%
1%