Unit installation

96
This option has a programmable range of 00 to 20. Setting the value to 00
disables the Fail to Comm, that is no event is recorded in the log. The number of
attempts made is always five therefore if Fail to Comms is programmed with a
value higher than five the comms failure is not recorded in the event log.
4 STU Options
If a Plug-on Subscriber Terminal Unit (3GSTU-PLI) is to be connected to a
Galaxy 16 plus (or Galaxy 16 with software V2.7 or later) then the Enable STU
option must be enabled. This allows the Control Output functions and STU
Line-Fail options on the Header pins to be programmed. The STU options need
not be enabled for 12 V (Non-plug on) STUs.
1 Enable STU
If a plug-on Subscriber Terminal Unit (3GSTU-PLI) is to be fitted to the Galaxy
16 plus then the STU option must be enabled.
To enable the STU option press the # key (the top line of the keypad should
read 1zENABLE STU), press the ent key to accept, or esc to cancel.
2 C/OP–Reset
There are three Control Output options on the Galaxy 16 plus: Reset, Set/Unset
and Remote Servicing. It is strongly recommended that only one of these
options is enabled on a Galaxy 16 plus control panel at a time. See also 3 C/OP
SET/UNSET and 4 C/OP-REM.SERV.
The Control Output Reset option, when enabled, allows the Galaxy system to
be reset after Intruder alarms by the central station.
To enable the C/OP-Reset option press the # key until the top line of the
keypad display reads 2zC/OP-RESET, press the ent key to accept. To disable
the C/OP-Reset option press the # key (the top line of the keypad display
should read 2C/OP-RESET), press ent to accept.
3 C/OP Set/Unset
The Control Output Reset option, when enabled, allows the Galaxy system to
be Set/Unset by the central station.
To enable the C/OP-Set/Unset option press the # key until the top line of the
keypad display reads 3zC/OP-RESET, press the ent key to accept. To disable
the C/OP–Set/Unset option press the # key until the top line of the keypad
display reads 3˜C/OP-Set/Unset, press ent to accept.
Note: It is strongly recommended that only one of the Control Output options is
enabled on a Galaxy 16 plus control panel at a time.
4 C/OP–Rem.Serv
The Control Output Remote Servicing option, when enabled, allows remote
servicing.