Unit installation

92
The programming of the telephone number is identical to the programming of
the main telephone numbers, see 12 Communications 1; 02 Telephone
Number 1.
The triggers for Home1 are programmed from menu option 13 Communica-
tions 2; 7 Home2 Triggs
.
14 Home3–Audible
The Audible alarms format will dial out an audible signal to the programmed
telephone number. On answering the telephone a Pulsed Tone will be heard for
Fire, PA, Intruder and Medical conditions. The different pulse times for each of
these alarm conditions are given in Table 6.3 Audible Alarm Pulses.
Table 6.3 Audible Alarm Pulses.
The tones for each alarm condition will be pulsed for a total of 40 seconds.
To enable the Home3–Audible triggers option enter a telephone number into
the menu option.
15 Home4–Audible
Home4–Audible acts as a backup to Home3–Audible. Its operation is the same
as Home3–Audible.
To enable the Home 4 Audible triggers option enter a telephone number into
the menu option.
12 = Communications 1 (cont’d)
mralAemiTnOenoTemiTffOenoT
eriFdnoces1dnoces1
APsdnoces2sdnoces2
redurtnIsdnoces4sdnoces4
lacideMsdnoces8sdnoces8