Unit installation
89
To programme the SIA triggers:
• Go to the triggers option and press the ent key.
• Trigger 1 Fire is displayed. If the box on the top line of the keypad display
is empty the trigger is disabled, if the box is filled the trigger is enabled.
• The # key toggles the enable status of the trigger.
• The A and B keys can be used to view the other triggers.
• Press ent to accept the programming or esc to cancel.
Figure 6.3 SIA Triggers Programming gives an example of programming the SIA
triggers, it shows how to enable trigger 4 Set/Reset.
Figure 6.3 SIA Triggers Programming.
08 Autotest
An Engineer Test can be automatically transmitted to the Monitoring Station at
programmed intervals. The engineer uses this option to enter the time that the
first Engineer Test is transmitted. Subsequent Engineer Test transmissions are
offset by the value in 09 Interval.
12 = Communications 1 (cont’d)
1
FIRE
#,1=ENABLE
(c)
Trigger four is currently
disabled.
(b)
Trigger 1 Fire is displayed with its
enable status (empty box= disabled).
4
SET/RESET
#,4=ENABLE
07=TRIGGERS
ENT,01—15=SELECT
(a)
Triggers banner.
4zSET/RESET
ENABLE
Press
ent
to select
the triggers option.
(d)
Trigger 4 Set/Reset is now
enabled.
8z
PART SET/UNSET
ENABLE
press
#
or
4
to toggle
the enable status of
the trigger.
(e)
Trigger 8 Part Set/Unset
enabled.
Use the
A
key to scroll through the triggers to trigger 4 Set/Reset.
Use the
A
or
B
key to scroll through the triggers, use the # key, or the
corrosponding No. key, to toggle the enable status of the displayed trigger.
Press
ent
to accept the
triggers programming (
esc
cancels).
07=TRIGGERS
ENT,01—15=SELECT