Specifications
October 2012 © British Telecommunications plc 2011
Page 34
When a PSTN call is attempted and fails to establish, a “Fail to communicate” event is logged
in this local log. For further debugging there is a “Device number” associated. i.e. Device 0/2
means the unit failed to dial the second telephone number.
Other typical messages that may appear in the log.
Telephone line restore. Device 0 PSTN has successfully dialled up after a fail.
Fail to communicate. Device 0/1 PSTN call to Telephone number 1 failed
Fail to communicate. Device 0/2 PSTN call to telephone number 2 failed
Panel upload Download.
Remote access to the alarm panel can be achieved using the redcare UDL facility. Contact
your redcare representative for details of accessing the redcare UDL servers.
Figure 19 - serial connection to Galaxy panel allowing remote panel access from Galaxy
Remote Service Suite
Roaming SIMs
The unit will auto detect the sim type that is present in the unit. Most units are supplied pre
fitted with a Roaming Sim. Where a Roaming Sim is fitted then the unit will switch between
GPRS networks to maintain connectivity should connectivity be lost on the current network.
The unit will search the available networks for a signal stronger than the “Roaming CSQ limit”
at unit start up. (Default 19)