Specifications
October 2012 © British Telecommunications plc 2011
Page 32
Predial number; default = blank. Any additional digits that may be required to be
dialled. i.e. 9 to obtain an outside line on PABX, 1740 to force CLI on, 1280 to force BT
routing.
Phone Number 1. Default = 08009173263. Telephone number of A side ESP servers.
Phone number 2. Default = 08009173265. Telephone number of B side ESP servers.
Username. Default = redcare@btinternet.com. Username for dialup RAS
Password. Password for dial up RAS.
Voltage fail delay. Default = 120s. Delay time before loss of PSTN voltage is reported.
(Pin 955 alarm). Also delay time before GPOP1 operates for loss of PSTN voltage.
Voltage restore delay. Default = 30s. Delay time before restore of PSTN voltage is
reported. (Pin 955 restore). Also delay time before GPOP1 restores for restoration of
PSTN voltage.
Panel settings
Panel type. Default = Pin. Future use will enable dial capture module.
Kiss Off window. Default = 0 ms. Future use allows dial capture kiss off time to be
extended.
Off line timeout. Default = 1500 minutes. Unit will reboot if no polls are received from
ESP over any path for this period of time. (1500mins = 25 hours)
Mains Fail time. Default = 7 minutes. Time delay before pin 13 alarm is reported.
Low DC fail time. Default = 1 minute. Time delay before Low supply voltage alarm is
reported. (pin 985 alarm)
General Purpose input sense settings.
Tick for positive applied triggering. Untick for positive removed triggering.
Inputs 1-8
Inputs 9-16
Line Fault Debounce time.
Wireline. Default = 2 mins. Time before GPOP1 will operate following IP path
failure.
Wireless. Default = 15 mins. Time before GPOP1 will operate following GPRS path
failure.
Dial IP. Default = 15 mins. Time before GPOP1 will operate following PSTN path
failure.
(Note: GPOP1 will restore immediately following path restoral).
General Purpose Outputs.
GPOP1. Default = BSIA form 175.
o BSIA form 175. Operate on either path fail, and respond to panel
interrogation on pin 11.