Installation manual

Windsor 500 Installation Manual - Issue C
-
7
-
CE Declaration
This product is compliant with the EC directive 89/336/EEC on
electromagnetic compatibility.
To comply with this directive it is essential to fit all 11 screws
when mounting the main control PCB into the case and to
avoid routing any cable under or over the main PCB.
This product complies with the requirements of EN 60950. The following information is
essential for the safe installation and operation of this equipment.
Mains
As the system uses hazardous voltages it is recommended that the mains supply connection
follows national wiring rules and is carried out by a suitably qualified person.
This equipment must be permanently connected to a mains fused spur (3A or 5A). Knockouts
are provided on the top and sides of this equipment and these are intended for conduit or
cable glands.
Mains Supply
Rated Voltage 230 V a.c. +/- 10%
Rated Current 270 mA
Mains Fuse 250v 630mA F
This class II equipment must be isolated from the mains supply before accessing hazardous
parts.
Auxiliary DC Supply
The DC supply output of this equipment is a Safety Extra-Low Voltage (SELV) circuit. The DC
supply rating is for all the DC requirements including recharging the battery. The supply has
the following rating;
Output Voltage 13.7 dc nominal
Continuous rated current 2.0 amp
PSU Aux. DC supply fuse rating 250v 1.0A type F
Battery supply fuse rating 250v 2.5A type F
Aux. DC supply fuse rating 250v 1.6A type F
Aux. DC supply (speaker) fuse rating 250v 800mA type F
All wiring in this enclosure requires to be V-2, IEC approved or PVC type.
The installation wiring within this equipment should utilise plastic cable ties to provide a means
of strain relief.