Installation manual
Windsor Installation Manual - Issue C
-
57
-
RS 232 Interface PCB
The Windsor RS232 Interface board connects to the communications port, CON 6, of the
main PCB. The function of the RS232 Interface board is to convert the TTL voltage levels on
the main PCB to the RS232 voltage levels. An RS232 Interface board will be required if you
are connecting Windsor to a PC, modem, PAKNET or X25 pad. It is not required if you are
connecting to SmartComm or Pacom. When connecting to a PC you must use a crossed
cable (RX-TX and CTS-RTS).
There are 2 types of RS232 Interface board used in Windsor. The Windsor mark 1 RS232
Interface board is identified as PC922 and has a 12 way connection to the main PCB and the
Windsor 500 RS232 Interface board is identified as either 22-00102 or PC841 and has a 15
way connection to the main PCB. Both types are fitted with a 25 male way D-type connector.
9 way D-Type 25 way D-Type Windsor Mark 2 - CON6 Windsor Mark 1 - CON6
1 +12V 1 +12V
3 2 2 TXD 2 TXD
2 3 3 RXD 3 RXD
7 4 4 RTS 4 RTS
8 5 5 CTS 5 CTS
4 20 6 DTR 6 DTR
6 6 7 DSR 7 DSR
1 8 8 DCD 8 DCD
9 22 9 RI 9 RI
10 No Connection 10 5v
11 No Connection 11 0v
12 +5v 12 No Connection
13 No Connection
5 7 14 0v
15 No Connection
Windsor RS232 Interface to PC (9 way D-Type) connections
Windsor PC
7
5
4
3
2 2
3
8
5
7