Installation manual
Windsor Installation Manual - Issue C
-
56
-
SmartComm
SmartComm is a combined dialler/modem which connects to Windsor on the
communications port. SmartComm is fully programmable from a Windsor keypad and can
share a telephone line with a telephone handset(s). SmartComm can be used to signal
alarms in ADEMCO fast format. As a modem SmartComm operates at 1200 baud and can
be used for downloading from a remote PC.
To install the SmartComm PCB in Windsor it must be mounted on the pillars provided. The
pillars are mounted directly to the chassis of the Windsor and the SmartComm PCB is
mounted on these. The SmartComm cable goes directly from CN1 on the SmartComm to
CON 6 on the main PCB. The cable and the mounting pillars are supplied in the SmartComm
installation kit. SmartComm is a combined Dialler/Modem for communicating with a central
station or for up/down load of information to and from the Windsor control panel. The
SmartComm is installed directly inside the Windsor control panel.