Installation manual

Windsor Installation Manual - Issue C
-
-
Windsor Modem
There are 2 variants of the Windsor modem;
W73535 Windsor 500/700 panel modem
W73534 Windsor Receiver modem for GuardStation
There is only one version of the Windsor modem software for all target countries. The
Windsor modem software has 3 pre-configured profiles which can be selected by using the
ATZn command. The profile usage is shown in the table. The profile contents are detailed in
the Windsor modem defaults section.
Command Profile
ATZ1 Windsor 500, Windsor 700 version 8, Windsor
modem Receiver.
ATZ2 Vigil V64 Mk2 panels using V23 mode
ATZ3 Vigil V64 Mk1a panels using V23 mode
Windsor Modem
Approvals
Country Approval Number
UK NS/3366/3/V/607064
Windsor Modem
PCB Connections
CN 3 Control Panel Interface 1 +12V
2 TXD
3 RXD
4 RTS
5 CTS
6 DTR
7 DSR
8 DCD
9 RI
10 ground
11 ground
12 No Connection
13 ground
14 ground
15 ground
CN2 Audio Interface 1 microphone 1
(not supported at present) 2 microphone 2
3 microphone 3
4 microphone 4
5 speaker out
6 ground
CN9 PTT Connection 1 BC
2 TB
3 B
4 ground
5 A
6 TA
CN10 DC power 1 +12v
2 0v