Internal Serial Bus
AV60
Tamper
Broadcast
Talkback
Sw Live
Channels 1 - 8 (12V - IN - 0V)
ISB
Socket
500mA
250V 20mm
For Link and Switch options see
notes
Telephone Socket
4
5
AV60
Connections
Connection Function
Audio 1-8 12v, +ve feed to microphone
IN Audio connection to microphone
0v, -ve feed to microphone
SW Live LED enable to microphone (common for all microphones)
Talkback Audio to Talkback unit
Broadcast Audio to Broadcast unit
Tamper tamper connections for all microphones
AV60
Switch Options
Switch Off On
1 Pre-record audio (jumper 4 in) Record from alarm (jumper 4 out)
2 Star services disabled Star services enabled
3 30 seconds record (jumper 5 out) 60 seconds record (jumper 5 in)
4 Live audio first Recorded audio first then live
AV60
Programming
Refer to the Edit/Hardware section of the Windsor programming manual.
AV60
Recording a Message
To record the site message;
1. Connect a telephone handset with DTMF capability to the telephone socket of the
AV60.
2. Press the * button on the handset.
3. Press 02 on the handset. The Green LED should come on. If the green LED does
not come on then remove all connections from the IN terminals. and retry.
4. Record the site name and site ID (maximum of 6 seconds).
5. Press #3 to exit.