Installation manual

Windsor Installation Manual - Issue C
-
-
If Handset and Line blocked are both programmed then line blocked and exchange voltage
monitoring will only be reported to the panel when the system (all areas) is set.
Connecting handsets in any configuration other than the method stated above (such as
parallel connection) will invalidate BABT (UK PTT) approval.
SmartDial Features
DTMF and Pulse dial
The communicator is capable of both DTMF and Pulse (loop disconnect) dialling of the
programmed telephone numbers. Dialling will only commence in the presence of a valid
proceed indication (dial tone) and will employ Timed Break Recall after 5 seconds in the
absence of the dial tone. If the exchange still fails to provide a dial tone, SmartDial will release
the line after a further 5 seconds. This will be considered as a connection attempt.
SmartDial Features
Timed Break Recall
The Timed Break Recall (“Star Services in UK) service available on digital exchanges in
many countries is employed at the dial time if no dial tone is detected. This action requests a
clear fresh line from the exchange and overcomes the malicious, or otherwise, blocking of the
telephone line. This feature is a programmable option in v2.07 or later. Note that the panel
software must be 2.07 or later.
SmartDial Features
Compatibility with BT Redcare
SmartDial can be successfully used on BT Redcare lines due to the filtering out of the STU
low frequency tone at the SmartDial telephone line input.
SmartDial Features
Locally Initiated Test Calls
A test call is initiated to the primary, secondary and dual reporting telephone numbers in turn,
in the format programmed for that telephone store. The result of test calls are entered into the
event log. Test calls in Ademco format will be signalled using the text channel (channel 9) and
will include the current status for channels 1-8.
SmartDial Features
Default Configuration
The contents of the SmartDial configuration can be defaulted to a known state by defaulting
the Windsor configuration.
SmartDial Features
Blind Dial
Normally the communicator will only dial if a valid dial tone is detected. In some
circumstances, such as dialling through a PABX or where the telephone exchange tones are
not reliable, it may be necessary to program the communicator to dial without recognising a
dial tone. This feature is a programmable option in v2.07 or later. Note that the panel software
also be 2.07 or later.