Installation manual

Windsor Installation Manual - Issue C
-
-
HS Concentrator
Connections
Connector Function Terminals
TB1 Control Panel Bus 1 - 12v
2 - Clock
3 - Data
4 - 0v
The screen terminal should be connected to
earth.
5 - Screen (optional)
CN12 Aux Power Output 1 - 12v
2 - 0v
Outputs supplied via fuse 1 3 - 12v
4 - 0v
CN4 Circuit 4 1 - 12v supplied from fuse 2
2 - detector input
3 - detector input
4 - 0v
CN3 Circuit 3 As CN4/Circuit 4 supplied from fuse 2
CN2 Circuit 2 As CN4/Circuit 4 supplied from fuse 2
CN1 Circuit 1 As CN4/Circuit 4 supplied from fuse 2
CN11 Aux Power Output 1 - 12v
2 - 0v
Outputs supplied via fuse 2
3 - 12v
4 - 0v
CN5 Circuit 5 As CN4/Circuit 4 supplied from fuse 1
CN6 Circuit 6 As CN4/Circuit 4 supplied from fuse 1
CN7 Circuit 7 As CN4/Circuit 4 supplied from fuse 1
CN8 Circuit 8 1 - 12v supplied from fuse 1
2 - detector input
3 - detector input
Day input is for use with an Excalibur sensor. LK8
4 - 0v
must be in the day position if day input is used.
5 - Day sensor input
CN9 Output 2 1 - +ve output
Output function is software programmable.
2 - +ve output
Refer to diagram for connections.
3 - -ve output
PL1 8 output programmable daughter board
CN10 Output 1 1 - +ve output
Output function is software programmable.
2 - +ve output
Refer to diagram for connections.
3 - -ve output