Installation manual
Windsor Installation Manual - Issue C
-
32
-
Vigil Concentrator
The Vigil concentrator operates in the same way as a Windsor concentrator. The main
difference is that a Vigil concentrator, when used in a Windsor system, can be addressed up to
concentrator 16. The connections to the Vigil concentrator are also different and are explained
in the following section. The Vigil concentrator (EOL and HS types) can be identified by the DIL
switch used for setting the concentrator address.
Vigil Concentrator
Connections
A Vigil concentrator is connected to Windsor in the same way as a Windsor concentrator but
the connection order is different as shown below.
Connector Function Terminals
TB1 Control Panel Bus 1 - 12v
2 - 0v
3 - Data
4 - Clock
Vigil Concentrator
Outputs
A Vigil concentrator has 3 outputs (PL9, PL10 and PL11). When used in a Windsor system
PL9 cannot be used. The other 2 outputs can be programmed as output 1 and output 2.
Windsor Vigil Connections
O/P1 PL10 PL10/1 -12v
PL10/2 - output
O/P2 PL11 PL11/1-4 - common output
The concentrator daughter board functions are the same on a Vigil concentrator and is
programmed as output 3.
Vigil Concentrator
Address Selection
The Vigil concentrator address is set using a DIL switch. The address table shows the DIL
switch positions when using a Vigil concentrator in a Windsor system
Windsor Address DIL Switches
5 4 3 2 1 0
Concentrator 1 0 0 0 0 0 0
Concentrator 2 0 0 0 0 1 0
Concentrator 3 0 0 0 1 0 0
Concentrator 4 0 0 0 1 1 0
Concentrator 5 0 0 1 0 0 0
Concentrator 6 0 0 1 0 1 0
Concentrator 7 0 0 1 1 0 0
Concentrator 8 0 0 1 1 1 0
Concentrator 9 0 1 0 0 0 0
Concentrator 10 0 1 0 0 1 0
Concentrator 11 0 1 0 1 0 0
Concentrator 12 0 1 0 1 1 0
Concentrator 13 0 1 1 0 0 0
Concentrator 14 0 1 1 0 1 0
Concentrator 15 0 1 1 1 0 0
Concentrator 16 0 1 1 1 1 0