Concentrator
Connecting Sensors
The concentrator connections for a sensor depends on the type of concentrator. The
connections are the same for both internal and external concentrator types. HS concentrators
are connected in the same way as a an EOL type but both resistors are 8k2.
EOL Connections NEOL Connections HS Connections
8K2
2k7
1
0v
4
3
2
12v
Concentrator
Detector
Alarm
Tamper
1
0v4
3
2
12v
Concentrator
Detector
Alarm
Tamper
8K2
8k2
1
0v
4
3
2
12v
Concentrator
Detector
Alarm
Tamper
There are special connection requirements for an Excalibur sensor. Refer to the light control
section of this manual for details.
Concentrator
PCB Links
Link Function Comments
LK1-LK3 Address links The concentrator addresses must be in
sequence from 1 up to the maximum
number specified in the System Size
programming option.
LK4 Day/Detector Select Selects the function of the circuit 8 input. If
an Excalibur day sensor is connected to
Windsor it must be connected to the DAY
terminal of PL10 and LK4 must be in the day
position. When LK4 is in the DAY position
terminals 2/3 of PL10 cannot be used.
LK5 Tamper disable Fit LK5 to disable the case tamper.
Concentrator
PCB Fuses
Fuse Type Function
Fuse 1 F100 mA/250V Aux. Power from PL1 and circuits
1-4
Fuse 2 F100 mA/250V Aux. Power from PL6 and circuits
5-8