Installation manual
Windsor 500 Installation Manual - Issue C
-
25
-
Inova Hardware
Wiring Details
Refer to wiring diagram (Main Circuit Board) on Inova Installation instructions.
1. On the main terminal block, terminals 1-4 should be connected to the control panel
user interface bus (CON 9 ).
Terminal 1 +12V
Terminal 2 Clock
Terminal 3 Data
Terminal 4 0 v
2. Refer to detail B, Inova Installation Instructions (Door Strike Wiring). The power
supply should be taken from one of the auxiliary power outputs on the Windsor main
board (CON 21), or alternatively a separate PSU.
Inova Hardware
Relay Connections
The alarm relay mimics the door contact at all times. Alarm and tamper can be wired to a
convenient circuit on an internal or external concentrator. For BS4737 Installations, the circuit
should be identified as an entry exit type (EnEx) for final door setting. If however, the Inova is
outside the protected area, the circuit should be identified as a NA alarm type.
Inova Cardpoint
Programming
The Inova Cardpoint unit is capable of interfacing with the Windsor Control Panel, enabling the
user to set or unset the alarm system (similar to a normal keypoint), in addition to normal
access control functions. Note, however, that the use of bank cards is precluded. All
programming events are verified via red/green LED indicators.
Inova Programming
Adding / Deleting Alarm Users
Specified users can be given authority to set or unset the alarm system. When you program
an alarm card user Windsor will set the authority automatically to “Inova” which allows only set
and unset. This authority can not be changed using a Windsor keypad or GuardStation.
Function Command Command Parameters
Add a new user #31# aaaaa #ii# aaaaa = the card number
ii = the user number ( 3 to 40 ).
Delete a user #33# aaaaa#. aaaaa = the card number
If a new alarm card is assigned to an existing user number then the old user will be deleted
automatically. It is not possible to add or delete an alarm card user if any area of the alarm
system is set, or if the engineer is logged on.
Alarm Panel Interface Functions
Specified users will be able to set and unset the alarm panel. While the alarm system is set,
access can be denied to all card holders until the panel is unset, or access can be permitted
only to those users with authority to unset the alarm panel. The alarm LED's on the Inova unit
(mains, ready, day and message) have the same meaning as those on a Windsor Keypoint.