User Interfaces
Inova Cardpoint
The INOVA Cardpoint has set and unset buttons and 4 status LEDs as standard. All
Cardpoints are connected to Windsor on 4 wire UI bus. The Cardpoint can be used as a
normal access control unit and to set and unset Windsor.
The normal guidelines for installing a standard Inova Access Controller should be followed.
This section details additional connections and programming required to interface the Access
Control Unit with the Alarm panel.
Windsor Status LEDs
Unset Button Set Button
Inova Cardpoint
Hardware
Inova Hardware
Addressing
All Cardpoints are identified by a unique address which is set using links on the Cardpoint
PCB. The Cardpoint addresses must be in sequence from 1 up to the maximum number
specified in the System Size programming option.
UI LK4 LK3 LK2 LK1
0 / / / /
1 X X X X
2 X X X /
3 X X / X
4 X X / /
5 X / X X
6 X / X /
7 X / / X
8 X / / /
/ Link Fitted